Hayward 1 12 Hp Super Swimming Pool Pump Sp2610x15 - Page 8 - Answered Questions & Fixed issues

0helpful
1answer

My Hayward H400FD is showing a H5 or HS error code, what does this mean, and what do i need to replace?

HS represents a problem with the temperature being too high. (maximum return water temp exceeded). this can be caused by a restriction in the plumbing system. i have that problem when i start my pool after a cold night. the water temperature rises too fast and the heater protects itself by flashing that code and turning off. reset the power to unit and it should work ok. if not, you may have to dig deeper as to why this code is being generated
12/20/2015 10:56:24 PM • Hayward Pool &... • Answered on Dec 20, 2015 • 8,028 views
0helpful
1answer

Error code hf hayward model h200ped2 after replacing control module

HF is a flame sense failure. make sure the off\on switch is in the on position (on gas valve in heater) if you are using an automation system, you should see BO when the pool is running and heat is not called for. if this is the case, you need to take the heater off of remote control and try to manually call for heat using the buttons on the heater. if it fires, that would make me think that there is a compatability issue between the new board on heater and old board on automation.
12/20/2015 10:51:07 PM • Hayward Pool &... • Answered on Dec 20, 2015 • 1,117 views
0helpful
1answer

My pilot light is lit but I am not getting fuel to the main source for heater to kick on.

could be pressure switch. that is the most common failure. otherwise, ensure gas pressure to unit, make sure gas valve switch is on (inside unit)
12/20/2015 10:41:17 PM • Hayward Pool &... • Answered on Dec 20, 2015 • 160 views
0helpful
1answer

How to fix a Hayward pool heater?

refer to owners manual, call technician
12/20/2015 10:27:04 PM • Hayward Pool &... • Answered on Dec 20, 2015 • 121 views
0helpful
1answer

Heater is smoking

when heater is cooled, remove top and clean out debris. if there is no debris, the color of smoke will indicate problem. white: condensation, rainfall etc burning off. black: burner not firing properly and sooting up. have unit serviced - clean burner assy, verify adequate gas pressure
12/20/2015 10:17:59 PM • Hayward Pool &... • Answered on Dec 20, 2015 • 2,160 views
0helpful
1answer

How can I get s240 manuals

http://www.hayward-pool.ca/pdf/manuals/ProSeriesCAN210T.pdf this is for the series: if it isnt a match, you can try the hayward US site
12/20/2015 9:51:18 PM • Hayward Pool &... • Answered on Dec 20, 2015 • 149 views
0helpful
1answer

Clarify wiring for haywood pump

without a pump model, it is impossible to provide information
12/20/2015 9:02:13 PM • Hayward Pool &... • Answered on Dec 20, 2015 • 184 views
0helpful
1answer

Just got a Hayward heater and installed it but it won't stay on it shows IF .

this error shows up when the system tries to fire (unsuccessfully) after three tries. make sure the switch inside is 'on', that the lines are bled properly of air and that all the shutoff valves are open
12/20/2015 8:15:50 PM • Hayward Pool &... • Answered on Dec 20, 2015 • 112 views
0helpful
1answer

I have a e50 Hayward filter and earth is getting past the fingers. There new fingers and don't have any holes in them.

the EC50 has a maximum flow rate of 50gpm. if your pump is too big, it may be pushing the dirt through the grids. flow rate of the pump should be on a panel on pump
12/20/2015 8:14:18 PM • Hayward Pool &... • Answered on Dec 20, 2015 • 200 views
0helpful
1answer

H100idp1. Why does it run but will not light?

it is possible that all conditions are being met for the safety features: water pressure, gas pressure etc. there might be air in the line (instead of gas) get a licensed technician to bleed the line to the heater. if you hear the clicking, the ignitor is firing. it might not be aligned properly for the burners to ignite. again, this is a job for licensed technician.
12/20/2015 7:58:42 PM • Hayward Pool &... • Answered on Dec 20, 2015 • 193 views
0helpful
1answer

Hayward pool heater rattling

this is caused by an obstruction in the water flow. check for blockages in both the supply and return piping
12/20/2015 7:51:13 PM • Hayward Pool &... • Answered on Dec 20, 2015 • 300 views
0helpful
1answer

Shaking heater is Hayward H4001DL

inside the header, there is a thermostat and a spring loaded bypass. my suspicion would be that the thermostat has failed and is not opening. this would cause an obstruction as the water tries to flow.
12/20/2015 7:37:18 PM • Hayward Pool &... • Answered on Dec 20, 2015 • 335 views
0helpful
1answer

Pool water will not circulate even though pump is running

if the water doesnt circulate, there could be many causes. start at the very beginning. does the pump sound 'normal'? if there is rattling or buzzing, the pump might not be turning and there fore no circulation. is there water in the system? even though most pumps are 'self priming', you should fill the hopper with water to prime it. are the lines open? make sure the supply to pump from skimmer is free of blockage and that the return lines to pool are open and free from blockage. if all this looks fine, then you have to get deeper into diagnosis.
12/20/2015 7:33:28 PM • Hayward Pool &... • Answered on Dec 20, 2015 • 271 views
0helpful
1answer

Pool overfilled, I thought because of rain. This wknd I backwash drained it to the proper level. 2 days later it was overfilled again...no rain. I don't know, but think I have an auto fill.

look for a smaller cover and open it up until you find something that looks like this one or even one that could look like a toilet fill... I've seen it. Thats the auto fill and they're relatively cheap, but to save you some money look for a little outlet (1-2" hole) in the pool right near the auto fill and plug it up with a rag. if water starts coming from the top of the fill area then it could be the filler or the fitting it connects to. Once you've determined if its the auto fill then shut the water off, most times it can be shut off with the landscaping but not always, you might need to shut off the water supply for a bit. then it just counter-clock screw out put in the new one and play with the levels you want it at. DONE!pool-overfilled-thought-because-rain-ustbplkubffqp2stvmj24pss-4-0.jpg http://www.amazon.com/Water-Leveler-Valve-Restrictor-Fountains/dp/B005SVW4UUhttp://www.amazon.com/Korky-528-Quiet-Toilet-Valve/dp/B00002N6MY/ref=sr_1_2?ie=UTF8&qid=1448043014&sr=8-2&keywords=leveler+fill+valve
11/20/2015 6:10:35 PM • Hayward Pool &... • Answered on Nov 20, 2015 • 782 views
0helpful
1answer

My Hayward H150 ED2 heater lights and burns for about 30 seconds and goes out. It has an error code of IF. We have checked the reccomendations but hasn't helped. Could it be the pilot assembly?

Try replacing thermocouple, pilot assembly usually includes t/C,check all wiring connections.
9/5/2015 6:41:28 PM • Hayward Pool &... • Answered on Sep 05, 2015 • 643 views
0helpful
1answer

My heater lights but turns off in a few seconds. error code ID

Just an idea, the gas goes bad in the line if the heater has been unused for a few months, I bleed the line at the valve. this is a common problem with motorhomes. the pilot lights, but the gas is weak and doesn't burn hot enough to tell the thermistor / thermocouple or the (bulb) there is a flame. OR check to see the flame is hitting the bulb, it might have got bumped during cleaning. but if the unit just up and quit, the thermocouple might have gone bad, and need replacing, and on some units can be a cheap easy fix. Hope I was of some help, and please get back to me with The Fix.. Your local pool pump repair guy longwood Fl 25830296-ur1txopp4wzzdayvijix1fdg-4-2.jpg
9/3/2015 3:23:26 PM • Hayward Pool &... • Answered on Sep 03, 2015 • 390 views
0helpful
1answer

Why does the switch on the back of the pump keep clicking?

the clicking you hear is a thing called a centrifugal switch , it engages below a certain speed to "cut in" the starting circuit , if you hear this continually click the power is shutting off or the speed of the pump is slowing down enough to engage this switch , this is not good as starting circuits are not designed to operate long , id first ck all your power connections ,might be a loose wire some place then if that's ok you can ck the speed of your pump using a strobe light (my phone has an APP for that!!) it would show your pump speed slowing down , this would need more investigation as to why this is occurring
9/3/2015 12:26:31 AM • Hayward Pool &... • Answered on Sep 03, 2015 • 163 views
0helpful
1answer

Can a Hayward s 166 t Hi rate sand filter be rebuilt

Parts can be replaced sure, but will it be worth it compared to buying a replacement or even upgrading. Laterals (if broken sand gets in pool) can be replaced on this unit from 48 off amazon and is cheaper than buying a new unit, same with leaking rings or seals. but if a part of the tank is cracked or something like that you might up spending almost as much to replace a piece of the unit as it would be buy a whole new unit. Amazon has this model for 180$ if repairs would cost more than 80 I would say replace it, these things dont last forever, especially if you live in a cold place that freezes in the winter and it sits in the sun all summer. hayward-s-166-t-rate-sand-filter-cva13tossffp5gzza31ixmk5-3-0.png Hayward S166T Pro Series 16 Inch Top Mount Pool Sand Filter Hayward SX164DA Lateral Assembly with Center Pipe Replacement for Hayward... Hayward SP0714T Pro Series Vari Flo Top Mount Control Valve Hayward SX164AA1 16 Inch Filter Body with Skirt Replacement for Select... There was also a couple smaller parts on amazon but you should check it out and also compare them to some other places.
8/10/2015 2:28:06 AM • Hayward Pool &... • Answered on Aug 10, 2015 • 235 views
0helpful
1answer

I just hooked up a hayward pro series sand filter and I am not getting any return flow into the pool. I followed the instructions to a T so I am unsure why I have no pressure or return flow....

Does the pump require priming? Most will need to be primed in order to create suction
I’m happy to help further over the phone at https://www.6ya.com/expert/david_66a56a0239b6ab32
7/29/2015 12:59:32 AM • Hayward Pool &... • Answered on Jul 29, 2015 • 99 views
Not finding what you are looking for?
Hayward 1 12 Hp Super Swimming Pool Pump Sp2610x15 Logo

57 questions posted

Ask a Question

Usually answered in minutes!

Top Hayward Pool & Spa Experts

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

john h

Level 3 Expert

29494 Answers

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Are you a Hayward Pool and Spa Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...