Hayward 1 12 Hp Super Swimming Pool Pump Sp2610x15 - Page 9 - Answered Questions & Fixed issues


either take out and reinstall with teflon tape or replace with new using teflon tape on threads

Hayward Pool &... | Answered on Oct 04, 2014 | 67 views


take off the top and side panels you should be able to see where the thermostat screws in and it goes to the front panel

Hayward Pool &... | Answered on Oct 04, 2014 | 54 views


I would ask that question at a pool supply,
& bring the broken parts with me

Hayward Pool &... | Answered on Oct 04, 2014 | 33 views


need new pump

Hayward Pool &... | Answered on Sep 28, 2014 | 340 views


go online to buy pool parts on line dot com match up your pump they have free shipping sometimes they helped me

Hayward Pool &... | Answered on Sep 12, 2014 | 257 views


it sounds like the motor has seized. if not seized, there may be something blocking the impeller. disconnect the power and try to spin the impeller

Hayward Pool &... | Answered on Sep 11, 2014 | 226 views


it depends on the size of the filter. there should be a tag on the filter body that will say exactly how much to put in.
http://www.poolsuppliescanada.ca/index.php?dispatch=attachments.getfile&attachment_id=161

Hayward Pool &... | Answered on Sep 05, 2014 | 32 views


if you are using a hayward control panel, either change the timer or push the 'service' button once. if it is a seperate timer, turn off the breaker to the timer

Hayward Pool &... | Answered on Sep 05, 2014 | 137 views


winterizing a filter is easy. turn pump off, remove the drain plug at bottom of filter. if its a cartridge filter, remove the cartridges and clean before reassembly. on a sand filter, put the dial valve in the 'close/winterize' position.

Hayward Pool &... | Answered on Sep 05, 2014 | 44 views


Hi, this is John the Hayward tech. If you are now seeing the #4 fuse go that is on the low voltage side. I would guess the main circuit board. I left a manual on your other post.

Hayward Pool &... | Answered on Sep 04, 2014 | 181 views


Hi, this is John the Hayward tech. Sounds like the mechanical seal is leaking. If you replace the spring loaded seal the problem could be that it was installed backwards. It is ceramic against carbon. if installed the other way it will leak. Any debris or oils getting on the seal will also cause it to fail Running pump without any water will heat up the seal and cause it to fail.

Hayward Pool &... | Answered on Sep 03, 2014 | 74 views


Hi This is John the Hayward tech. Have you received an answer. If not can you let me know the model of the filter and exactly what you are trying to accomplish. Thanks.

Hayward Pool &... | Answered on Sep 03, 2014 | 35 views


Hi, this is John the Hayward tech. Can you tell me if this is a heater or pump and which model. A picture would help me help you.

Hayward Pool &... | Answered on Sep 03, 2014 | 63 views


motor is overheating the thermo is shutting it off for safety need a new motor or pump sometimes the whole pump is cheaper than fixing the old one

Hayward Pool &... | Answered on Aug 30, 2014 | 89 views


through the skimmer

Hayward Pool &... | Answered on Aug 30, 2014 | 37 views


remove the ignitor wire (remember where they go try it again if it doesnt blow fuse you have a bad ignitor

Hayward Pool &... | Answered on Aug 30, 2014 | 130 views


you dont you either replace themotor and seals or get a new pump

Hayward Pool &... | Answered on Aug 27, 2014 | 80 views


need more info is wiring correct is it on a timer check on side of motor see what power is coming in you might have to change wires if 120 volt

Hayward Pool &... | Answered on Aug 25, 2014 | 72 views


if you have an universal pressure switch there is no adjustment. down turning the set point is a poor idea. this can allow the heater to run while the pool pump is only running at half prime or with less water flow. possible over temp situation can easily occur

Hayward Pool &... | Answered on Aug 20, 2014 | 428 views


check to see if filters are dirty or if a sand filter back wash or put on recirculate then see if more flow

Hayward Pool &... | Answered on Aug 17, 2014 | 30 views

Not finding what you are looking for?
Hayward 1 12 Hp Super Swimming Pool Pump Sp2610x15 Logo

57 questions posted

Ask a Question

Usually answered in minutes!