Refrigerators Logo

Related Topics:

A
Anonymous Posted on Jun 06, 2019

Part number for evaporator replacement fan from Beverage Air model KR48-1AS

5 Related Answers

A

Anonymous

  • Posted on Jul 02, 2007

SOURCE: BM-23 Evaporator fan motor

mine runs all the time.

Ad

Anonymous

  • 462 Answers
  • Posted on Apr 01, 2009

SOURCE: fan runs all the time

The inside fan has to run all the time. It turns off it will not keep things cold. Not the fan outside in the air it shoulc cycle with the compressor.

bobicehouse

Robert Moller

  • 1524 Answers
  • Posted on May 20, 2009

SOURCE: Replacing temperature control on a True beverage cooler

Remove the doors, then the evaporator cover. Just be careful.

Dennis Boxerman

  • 1306 Answers
  • Posted on Oct 10, 2010

SOURCE: I have a beverage air kegerator that seems to work

as a general rule,coolers have the fans run 24/7. Freezers will have the fans shut off during the defrost cycle. If unit maintain temp., I'd not be concerned by it.

Dennis Boxerman

  • 1306 Answers
  • Posted on Nov 28, 2010

SOURCE: beverage air model UR30G, not cold, fan still running

check the thermostat for proper setting, evap could be frozen up, the condenser fan could not be running, unit could be low on freon. start check some items and let me know.

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

I need to replace the condenser fan motor in a model MT27 Beverage Air Cooler. This motor is behind the evaporator coils and extremely hard to get to.

sounds like you need a professional. condenser is outside, evaporator is inside. what is your question, do you need me to come hold it?
2helpful
1answer
1helpful
1answer

Beverage Air. Model: CFG24-1. The evaporator fan motor does not turn while unit is operating. The entire condensing unit is working, except the evaporator fan motor. When I removed the evaporator fan motor...

http://beverage-air.com/pdf/manualsbycategory/K%20Series%20-%20Bottom%20Mount%20Reach-Ins/CFG_CRG_KF_Series809-046A.pdf

The fan has a limit control wired in series that shuts the fan down until the coil temperature reaches 25*F. this prevents the fan from blowing warm around after defrost.
There is also a switch which is placed for the door to close. Either one may be defective.
Worst case is the freezer is not pulling down temperature wise.
0helpful
1answer

Need to see if evap fans r working

http://www.beverage-air.com/uploadedFiles/docs/CFG_CRG_KF_Series809-046A.pdf
this site has your manual and the manual has wiring diagram.
also has some common trouble shooting questions and answers.
2helpful
2answers

I have a beverage air kegerator that seems to work fine, but the evaporator fan runs constantly. Is it supposed to run constantly, or is it supposed to cycle on and off with the compressor, etc.?

Most evaporator fans run all the time. This is mainly to use the air flow to assist in melting off any frost build up during the compressor off cycle. If that fan shut off with the compressor the coil will have a tendency to freeze up. :)
0helpful
1answer

Beverage-Air KF48-1AS not coooling, fans not running

some thing wrong with the evaporator fan motor. make sure the motor turns freely. your going to need service .
1helpful
4answers

Beverage air model UR30G, not cold, fan still running

check the thermostat for proper setting, evap could be frozen up, the condenser fan could not be running, unit could be low on freon. start check some items and let me know.
0helpful
2answers
0helpful
1answer
Not finding what you are looking for?

58 views

Ask a Question

Usually answered in minutes!

Top Refrigerators Experts

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Brad Brown

Level 3 Expert

19187 Answers

john h

Level 3 Expert

29494 Answers

Are you a Refrigerator Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides