My Frymaster is beeping and coming up with a

Temp got to hot and shut down high limit. Also check for a broken wire to high limit
4/19/2012 9:31:06 PM • Frymaster Dean... • Answered on Apr 19, 2012 • 506 views
0helpful
2answers

Frymaster fryer keeps calling for help on electronic keyboard.

There should be some kind of spark sensor usually where the gas line plugs into the pot. There is one wire hooked to it take the sensor out and clean it good. Soot could be building up on it causing it to nolonger sense a flame.
4/19/2012 8:44:56 PM • Frymaster Dean... • Answered on Apr 19, 2012 • 1,359 views
0helpful
1answer

Getting loud feed back

I would contact Frymaster at 1-800-551-8633. Ask for tech support.
2/24/2010 11:30:08 AM • Frymaster Dean... • Answered on Feb 24, 2010 • 66 views
0helpful
1answer

Frymaster FM345EBLCSD Alarm

Hi, As per our session, No. The sounders are probably bad or may have been hooked up backwards upon reassembly. GCS in KC would be the ones to contact for parts. Thanks for your business. If I can be of any more assistance, let me know. kstfas
8/28/2007 9:11:48 PM • Frymaster Dean... • Answered on Aug 28, 2007 • 246 views
0helpful
1answer

My Frymaster SR114 electric fryer keeps tripping

Defective thermostat.
8/29/2015 6:54:30 PM • Frymaster Dean... • Answered on Aug 29, 2015 • 566 views
0helpful
1answer

Pilot light will not stay on

Defective thermocouple. It is the metal tube that is in the flame of the pilot light.
8/29/2015 6:40:10 PM • Frymaster Dean... • Answered on Aug 29, 2015 • 416 views
0helpful
1answer

How to clean blocked pilot orfice

One time this happened to me on a gas stove. I used an electric drill with drill bit to clean it out. It will only work if the line is straight, no bends in the line.
8/29/2015 6:25:18 PM • Frymaster Dean... • Answered on Aug 29, 2015 • 147 views
0helpful
1answer

How do you release the grease

Here's a link that may help,find your model and click on it,k. http://www.frymaster.com/minisite/service/manuals
8/4/2015 3:22:53 PM • Frymaster Dean... • Answered on Aug 04, 2015 • 192 views
0helpful
1answer

Do i need a pressure regulator

always
7/1/2015 12:17:08 AM • Frymaster Dean... • Answered on Jul 01, 2015 • 228 views
0helpful
1answer

My deep fryer pilot light dose not stay light, why is it happening?

This might be due to a loose wire in the light that or it is going out.
2/17/2015 11:48:51 PM • Frymaster Dean... • Answered on Feb 17, 2015 • 107 views
0helpful
1answer

I'm not sure of the name of the parts, when the fryer is turned on flames come out of the bottom of the three front pillars? I'm not sure how to stop the problem. I've removed them and cleaned out so

Drill out all the small holes on the burners(pillars). Remove them by taking out the two bolts at the top of each burner.
1/27/2015 1:54:23 PM • Frymaster Dean... • Answered on Jan 27, 2015 • 158 views
0helpful
1answer

Can anybody tell me what's wrong with this? Any suggestions please and thank you.

The burner or the burner venturi is clogged. The burners are held in place with 2 bolts at the top and you need a 1/2 inch wrench. Remove the bolts and lift the burners off the brass orifices. Make sure all the holes are clear. If they are clogged they need to be drilled out. You should not have yellow in the flames in the burner tube.... kinda looks like the are sooting. This causes flames to come out the bottom of the burners.
1/27/2015 1:52:12 PM • Frymaster Dean... • Answered on Jan 27, 2015 • 136 views
0helpful
2answers

Pilot light lights but is a low flame

There is an adjustment screw on the main gas valve, usually under a cover screw. It will be near where the small pipe that goes to the pilot light.
7/30/2014 10:24:33 AM • Frymaster Dean... • Answered on Jul 30, 2014 • 206 views
0helpful
1answer

Flames come out from the pilot area heavy until unit gets to temp

venting is bad ---- soot build up - obstructions---------clean your unit
3/5/2014 5:38:50 PM • Frymaster Dean... • Answered on Mar 05, 2014 • 89 views
0helpful
1answer

Deep fryer pilot is blown out when burners go out

Hi there. Hi limit may be tripping off due to high oil temperature (power supplying the gas valve is connected in series with the hi limit). Verify if the thermostat is not shorted, also please check the thermostat calibration if it is good. Regards.
11/22/2013 3:15:04 AM • Frymaster Dean... • Answered on Nov 22, 2013 • 1,163 views
0helpful
2answers

SR 142 GP, flames shoot out of exhaust stack to

First look down the stack, with the fryer off, and see if there is something that fell down in there. If that is not the case then check to ensure that all of the burners are on when you turn the fryer on. If those check out OK then you probably have soot buildup in the burner tube. Remove the burners and clean out the tubes.
11/5/2013 2:22:49 PM • Frymaster Dean... • Answered on Nov 05, 2013 • 767 views
0helpful
1answer

How do I replace the high end thermostat

I need to replace it
9/23/2013 6:12:51 PM • Frymaster Dean... • Answered on Sep 23, 2013 • 65 views
0helpful
1answer

The fryer burners and pilot works fine but when I try to turn it off by the thermostat the fires go down a little but won't cut off, what could cause this

Likely one of two things. The thermostat is stuck on or your gas valve is bad. Identify one of the wires going to the thermostat and disconnect it, if the burners shut off with the thermostat disconnected the problem is the thermostat, otherwise it will be the gas valve. All this assumes the unit is wired correctly and has not been changed. If your burners are not shutting off due to a bad gas valve or thermostat you are at risk to have a fire! Be sure to get this fixed immediately and it is unsafe to operate the fryer until repaired.
4/29/2013 3:37:59 AM • Frymaster Dean... • Answered on Apr 29, 2013 • 601 views
0helpful
1answer

Frymaster pump and motor

Hi there.Filter paper may be clogged causing the pump motor to trip-off after the filtration of the second fryer, better scrape off any filtered debris on paper afrte filtering.Also oil temperature must be at least 250F or above to lessen the load on pump motor as oil with low temperature is thicker than oil with high temperature.Regards.
7/12/2012 7:34:08 AM • Frymaster Dean... • Answered on Jul 12, 2012 • 496 views
0helpful
1answer

Verified thermopile produces 700 milivolts, but pilot still goes out.

Hi there!Check the hi-limit by removing the wire at terminals and connecting an ohm-meter across, it should have continiuty, if it does not have, better replace it with a new one.Regards.
7/12/2012 6:12:43 AM • Frymaster Dean... • Answered on Jul 12, 2012 • 153 views
Not finding what you are looking for?
Frymaster Dean H22 Deep Fryer Logo

5 questions posted

Ask a Question

Usually answered in minutes!

Top Frymaster Dean Kitchen Appliances - Others Experts

Paul Carew

Level 3 Expert

3808 Answers

Thomas Perkins
Thomas Perkins

Level 3 Expert

15088 Answers

Are you a Frymaster Dean Kitchen Appliances - Other Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...