Hi - here are the instructions to help with your project
1. Isolate from power.
2. To remove the outer door panel, remove the eight screws securing it to the inner door panel. Be careful of sharp edges.
3. To remove the handle, remove the six torx drive screws securing it through the inner door panel.
4. Refit in reverse manner.
Note: 230 volts is still present at the detergent dispenser and electronic P.C.B. unless power is isolated at the plug outlet or mains.
Location: The door handle latch is located within the centre of the handle moulding
and is retained by a pivot latch. The microswitch is situated on the side of
the latch and is clipped in.
After isolating the machine from the power supply:
1. Remove outer door and handle (refer Section 6.2).
2. Remove the latch by sliding it away from the P.C.B. console.
3. Unclip the microswitch from the latch.
4. Ensure the springs and microswitch lever are fitted to the latch when re-assembling.
Refitting: Refit in reverse manner.
Sorry I cannot provide a sketch for public view, I may get into trouble.