SOURCE: F1 Error on Fisher & Paykel Nautilus
It leaked before leading to this.
1- Unplug the power.
2- Dry out the leak.
3- Before taking off the lid seal, check if Lid actuator working by going to diagnostic mode. 4- Select LD.
5-Pull the drawer half way out so you can see the lid going down or not when you turn on by pressing lock button.
6- Press the lock button again to release the Lid.
7- Most the time it is a Lid actuator problem and your seal look good, then you replace the Lid actuator only.
8- If it is a problem with the Lid actuator and your seal look bad then replace all .