Computers & Internet Logo

Related Topics:

Posted on Feb 03, 2011

I have a Dell PowerEdge 1850 Server where there is no display, but the powersupply units are working. There is no power coming to the board.

4 Related Answers

A

Anonymous

  • Posted on Dec 09, 2007

SOURCE: Dell PowerEdge 840

Look in Bios setup for OS Install mode setting. If it is enabled, it restricts the RAM to 256MB. Change the setting to off and it will sense the total RAM

Ad

Anonymous

  • 1 Answer
  • Posted on Jun 11, 2009

SOURCE: Flshing Red Light on Dell Poweredge 1800 Server

I finally made contact with our IT dept who were abole to carry out a remote diagnostic test.

Problem has now been identified (problem with tape drive)

Shawn DuRee

  • 356 Answers
  • Posted on Jun 07, 2010

SOURCE: No power on my PowerEdge 1800 Server

dells power supplies must come from dell. I would call dell and give then the service tag number of your server and they will be able to tell you about how much a power supply is.

Anonymous

  • 2 Answers
  • Posted on Sep 30, 2010

SOURCE: dell poweredge 830 server orange flashing light

its the cover switch. there is a small push switch on the front panel that detects if the front cover has been removed, either the switch is defective, or the cover is not seating properly to close the switch.

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

Where is poweredge 1800 display led connector

http://www.dell.com/support/troubleshooting/us/en/19/KCS/KcsArticles/Print?he Embedded System Management (ESM) log - also called System Event Log (SEL) or hardware log - reports potential hardware problems in Dell PowerEdge servers. Sometimes, simply turning off the server and disconnecting it from the electrical outlet will remove the error message. Wait approximately 10 seconds, and then reconnect the power cable and restart the server.

Other times, you will need to clear the ESM log to remove the error message. For instance, error code SEL FULLindicates that you will need to clear the ESM log. (You will lose the server's event history.) There are different ways to clear the ESM log.

To use DSET to Clear the ESM Log
  1. Download and open the DSET utility.
  2. Click the plus (+) next to System, and then click the plus (+) next to Logs.
  3. Click ESM to highlight it.
  4. Click Clear ESM Log located in the upper-right corner of the page.
To use OpenManage Server Administrator (OMSA) to clear the ESM log
  1. Start OpenManage Server Administrator (OMSA).
  2. Log in to OMSA by entering your username and password, and then press Enter.
  3. Click the Logs tab, and then click Hardware.
  4. Click Clear Log located next to Options.
To use Dell IT Assistant to clear the ESM log
  1. Start IT Assistant.
  2. From the middle System Tree bar, select your server by clicking it.
  3. Click the Logs tab, and then click Clear Log in the upper-right corner of the page.
Find your Dell PowerEdge server model in the chart below for other ways to clear the ESM log:

PowerEdge server model How to clear the ESM log 2300, 2400, 2450, 2500, 2500SC, 2550, 4300, 4350, 4400, 6300, 6350, 6400, 6450
Use the Log2Txt.exe utility to clear the ESM log:
  1. Start your server to the Log2Txt utility.
  2. When you see the ESM Log main menu appear, press 2 on your keyboard to select Clear ESM log.
  3. When the ESM Log main menu reappears, press 5on your keyboard to exit the utility.
1650, 1850, 1800, 2600, 2650, 2800, 4600, 6600, 6650, 7150, 6800, 6850, R900
Use the DRAC or ERA to clear the ESM log:
  1. Type the IP address of the Remote Access Controller (RAC) in the web browser address bar, and then press Enter.
  2. Log in to the RAC.
  3. Click the Logs tab, and then click Hardware.
  4. Click Clear Logs located in the upper-right corner of the page.
1850, 2800, 2850, 6800, 6850
Use the program BMCCFG.exe to clear the ESM logs:
  1. Download and extract the Dell OpenManage Deployment Toolkit here.
  2. Go to x:\Dell\Toolkit\Tools, where x is your primary hard disk drive.
  3. Copy the file BMCCFG.exe to a bootable floppy disk.
  4. Start the server from the bootable floppy disk.
  5. At the command prompt, type bmcc - clearsel, and then press Enter.
    The message "Clearing SEL" will display while the log clears.
1950, 2900, 2950, DP500, DP600, NF500, NF600
Use the BMC/BIOS to clear the ESM log:
  1. To open the BMC menu, press the Control + Ekeys during POST.
  2. From the list, select System Event Log, and then press Enter.
  3. Select Clear System Event Log, and then pressEnter.
=8590&doclang=EN
0helpful
1answer

How do i see a power supply failure on t100 dell?

you dont, try connect tester for powersupply or use a standard volt-tester see if you got 5 volts and 12 volts working
0helpful
1answer

1850 dell monitor problem

try new cabels, reseat, diff monitor. the onboard video might be bad
0helpful
1answer

Dell Poweredge 1800 server not start, i press power button but nothing hapened

Your Model of Dell Poweredge 1800 server may not have a redundant power supply. The power supply is the most like cause of the problem. order a replacement power supply and replace the faulty unit.
1helpful
1answer

Hi, my Dell PowerEdge 1850 Server freeze at boot screen after print remote access controller detected. anyone ve any solution on it ?

I had exactly the same issue, its basically your iDrac card thats likely at fault. I simply removed mine and the server would boot as expected. If you require the iDrac then order a new card and this should solve your issue.
1helpful
1answer

My dell server poweredge 2850 sound like jet taking off

This is perfectly normal for this server. It powers on, the fans come on all at once and then, dial back down to a loud whisper. All Dell 1850, 2850, 1950, and 2950 servers do the same thing. It does no harm to the server whatsoever and is a normal part of the initial power up process.
0helpful
1answer

My monitor is not displaying anything, not even the bios screen. My vga connectors and power cords are plugged in.

The only suggestion I would have is to pop the liod off and plug in a video card (I know its a 1u unit, but keep the lid off - this is just to test. If the vid card you popped in gives an output then onboard is shafted, with a 1u, not much can be done apart from new mainboard... or just remote desktop from another machine if it boots?
2helpful
3answers

Poweredge 2600 power supplies in red

Possibly a power distribution board problem.
PDB requires replacement.
Not finding what you are looking for?

246 views

Ask a Question

Usually answered in minutes!

Top Dell Computers & Internet Experts

Grand Canyon Tech
Grand Canyon Tech

Level 3 Expert

3867 Answers

SmartAviator
SmartAviator

Level 3 Expert

1124 Answers

Brad Brown

Level 3 Expert

19187 Answers

Are you a Dell Computer and Internet Expert? Answer questions, earn points and help others

Answer questions