On some of the maytag washers when an unbalanced load stops the maching it blows an internal fuse located behind the front panel on some stacking washer and dryer machines and under the counsel on some of the top load machines. ON the top load machines it is recomended that you change the lid switch with the fuse that comes with it.
There are two screws located on each side of the counsel. Remove the two screws and tilt the counsel up and locate the lid switch, fuse assembly. You can check the fuse at this point.