Honda ES6500k2A generator will not start. Oil,coolant and fuse are OK. No sediment in bowl. cannot find any jet to clean. Starts with fluid, but stops. Float is working

Main jet on carb is clogged. Starts when you prime but then will shut off. Remove and disassemble carb taking pains to thoroughly clean the main jet area with cleaner. Check the holes that you have in the bolt that holds the bowl in place - they must be clear! Spray cleaner up the tube that runs into the bowl.
8/28/2015 7:08:54 PM • Honda Electrical... • 111 views • 0 helpful votes
0helpful
1answer

My trusty old honda 3000 is generator keeps on stalling out but always starts up immediately again could it be that it has been running three days long noe and overheating?

THERE COULD BE SEVERAL CAUSES; THE VOLTAGE REGULATOR, THE CARBURETOR, THE OIL LEVEL. ALL NEED TO BE CHECKED.
6/16/2015 8:41:51 AM • Honda 3000 Watt ... • 547 views • 0 helpful votes
0helpful
1answer

I have Honda generator 4100 with remote start it will start and run untill u let off botton light on remote switch went out how do dy pass switch

PDF]SERVICE MANUAL - Electric Generators Direct

www.electricgeneratorsdirect.com/manuals/NGK%20Generator%20Hond... associated with operating your NAC portable generator, following the precautions listed below will assist you in .... For detailed engine information, refer to the Honda Engine Shop Manual. Note: ? ..... (e) Do NOT remove the diodes or de-solder the wires attached to the diodes. (f) Ensure you have ... NDK-4100YE. WIRING ...
8/4/2015 12:45:26 AM • Honda Electrical... • 140 views • 0 helpful votes
0helpful
1answer

Not getting fuel

If it's sat for a long time, take out and clean the air and fuel filter for starters. I'd clean or replace the fuel lines as well. A good trick that I've used many times is gas line anti-freeze (methyl hydrate), same stuff they use to octane boost. Don't over mix it, but make sure it runs a little higher than normal for a minute or two, like getting the carbon out on the freeway, cleans it right out. Ether (sure start) works very well, but it's very easy to use to much and/or cause damage, to the machine and you, so I only recommend that for emergency situations. Asides, methyl hydrate is a lot cheaper. Hope I helped, Grim
8/19/2015 12:24:52 PM • Honda EU3000iSAN... • 81 views • 0 helpful votes
0helpful
1answer

How do you fix a Honda generator 1000i no power at out let.

take it to a generator repair shop as there are associated risks if you do it your self
7/21/2015 5:11:06 AM • Honda Electrical... • 175 views • 0 helpful votes
0helpful
1answer
0helpful
1answer

Service manual required

I can't find a free download on the internet, most are Owner's manuals or are not for the exact model you want - I don't know how similar similar models are. You might try the following: http://cdn.powerequipment.honda.com/pe/pdf/manuals/00X31Z376011.pdf (from Honda, EU7000is owner's) Honda EU7000i Model Info Super Quiet 7000 Watt Inverter Generator Honda... This is the shop manual for the EU6500is model ($44) Honda EU6500is Generator Shop Manual owner's for the EU6500is http://www.freeproductmanual.com/honda-eu6500is-manual Finally a link to the search results most of the were taken from https://uk.search.yahoo.com/search;_ylt=A9mSs2tVBShVngQA_xZLBQx.;_ylc=X1MDMjExNDcxNzAwMwRfcgMyBGZyA2FsdGF2aXN0YQRncHJpZANyOTBfV1hQeVNvT0twcW5oS3NxWlFBBG5fcnNsdAMwBG5fc3VnZwM0BG9yaWdpbgN1ay5zZWFyY2gueWFob28uY29tBHBvcwMwBHBxc3RyAwRwcXN0cmwDBHFzdHJsAzMwBHF1ZXJ5A0hvbmRhIEVVNjUwMGlzQSBzZXJ2aWNlIG1hbnVhbAR0X3N0bXADMTQyODY4NjQ3NQ--?p=Honda+EU6500isA+service+manual&fr2=sb-top-uk.search&fr=altavista You could try contacting Honda (relevant division) also; if they will provide the manual you want, it might be free 10.April.2015
4/10/2015 4:31:05 PM • Honda EU6500isA... • 1,266 views • 0 helpful votes
0helpful
1answer

Honda em7000is generator has no spark what could it be

BEST VIDEO TO SHOW THE PROCEDURE TO TROUBLESHOOT, HOPE IT HELPS... https://www.youtube.com/watch?v=Wi5gTyyHUIU How To Diagnose Repair Generator With No Spark Ignition Module Replacement
3/29/2015 5:16:22 AM • Honda Electrical... • 1,538 views • 0 helpful votes
0helpful
1answer

Old Honda eb1500x is putting out low voltage but engine seems to run fine. Ideas for testing and fix?

Couldn't find anything on that model number other a control box.Assuming your in the USA output frequency would 60 hertz under load so 65 hertz would be find; although, engine is running close to 3900 rpm when it should be around 3750 rpm unloaded which would be 62.5 hertz. As the output voltage being low it is probably the AVR (automatic voltage regulator) that is the problem.
5/28/2015 7:08:55 PM • Honda Electrical... • 229 views • 0 helpful votes
0helpful
1answer

How many watts does it need to run the airconditioner.Is a honda 3000 good enough

You can check the AC unit, it will tell you how much electricity it needs. Likely 15 or 20 amps. That's about 1500 or 2000 watts. What does your generator supply?
6/23/2015 11:16:53 PM • Honda Electrical... • 83 views • 0 helpful votes
0helpful
1answer

Where is 10A fuse holder on honda ex5500 generator

Usually on the power board under a black grub screw which you should be able to undo by hand.
4/22/2015 9:55:06 PM • Honda Electrical... • 319 views • 0 helpful votes
0helpful
1answer

Honda generator problem error code 04 how to clear

I have a video that may help you to troubleshoot the problem. https://www.youtube.com/watch?v=zGy9WoA537w&list=UUycoCur2JWPEhrS0qTeyIJw Please let me know what you find I am happy to help further. Joe barterjoes.com
1/27/2015 7:59:03 AM • Honda Electrical... • 2,194 views • 0 helpful votes
0helpful
1answer

How do I stop oil coming out of the exhaust?

If it is a four stoke " no oil mix required " Oil out the exaust can only mean oil is getting past the rings, valve stem seals are worn " if seals should only smoke briefly after start and go away " or oil in the gas...first check for oil in the gas..Should show on the dip stick..if none or you can't detirmine change with new gas..the run for a while any oil residue will burn off and smoke clear..if still smoke..your rings on the piston are wearing out or your piston cylinders may have small scores " scratches " allowing the oil to pass by and into the combustion chamber..Also your spark plugs should be showing oil residue on the tips if oil is being burnt...Easy fix first..buy a can of restore or any good prouduct to help restore the cylinder walls..I use RESTORE BRAND a little expensive but worked very well for me..run a tank of gas through it to give it some time to seal the scratches on the cylinder walls and Pistons..if it works for you add a little with each oil add/or change....if this does not do it..sorry but a rebuild is needed.. and Good luck..
3/2/2015 3:17:15 PM • Honda Ex350 350... • 501 views • 0 helpful votes
0helpful
1answer

Why won't my Honda ez 1400 generator start?

Check the igni system
4/11/2015 9:34:56 AM • Honda Electrical... • 159 views • 0 helpful votes
0helpful
1answer

HONDA EX5500 HAS HIGH VOLTAGE WHEN COLD AND SOMETIMES INTERMIITTEN HIGH VOLTAGE OVER 300 VOLTS ON METER IS IT A BAD AVR OR CONDENSER

Check this site about fixing the AVR or inspecting it. Likely you have an issue with the AVR if any tapping causes changes. What is involved in generator service
2/11/2015 4:18:54 PM • Honda Ex5500... • 757 views • 0 helpful votes
0helpful
1answer

Alve gap on a Honda GX390 engine? Hi, I have a gas generator with a Honda GX390 engine in it. I need to adjust the valves. Any idea what the gaps are supposed to be? Also do I adjust on a cold engine

GX390K1 Intake 0.15 +/- 0.02mm ( 0.006 +/- 0.001in ) Exhaust 0.20 +/- 0.02mm ( 0.008 +/- 0.001in ) Usually done with the engine cold/
2/23/2015 10:45:39 PM • Honda Electrical... • 530 views • 0 helpful votes
1helpful
2answers

Runs well for a shot tims then stalls at high arpiems itnis not the carbs or fuel pumps could it be the coil

Not the carbs, not the fuel pumps, maybe the fuel delivery volumes to the carbs by the fuel pumps. A restriction can cause the engine to suck the carburators fuel bowls dry if not enough volume of fuel is delivered. Do a fuel volume test
4/16/2015 5:15:04 PM • Honda outboard • 115 views • 1 helpful votes
0helpful
1answer

Point gap wanted for honda 300u generator

General rule of thumb for point gaps. 25 thou. Hacksaw thickness Should work fine.... it's not a precision machine?
3/6/2015 7:57:01 AM • Honda Electrical... • 314 views • 0 helpful votes
Not finding what you are looking for?
Honda Logo

839 questions posted

Ask a Question

Usually answered in minutes!

Top Honda Electrical Supplies Experts

vince

Level 3 Expert

2530 Answers

Paul Carew

Level 3 Expert

3808 Answers

Brad Brown

Level 3 Expert

19187 Answers

Are you a Honda Electrical Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...