I have a UPS Smart 5000va model :surtd5000xli I replaced all new battery for ups but when i started ups all leds in the battery column litting .I want to connect ups and pc to reset new battery (this ups have not serial port ,it have rj45 port ).Please tell me how i connect between pc and ups.Which program i will to run for reset battery (i used com port rs 232 to reset battery for ups smart 3000va and terminal program in pc to reset ups smart 3000vas ok )

1 Answer

Gruber Power Services

Level 2:

An expert who has achieved level 2 by getting 100 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Mentor:

An expert who has written 3 tips or uploaded 2 video tips.

  • Expert 176 Answers
  • Posted on Oct 26, 2011
Gruber Power Services
Expert
Level 2:

An expert who has achieved level 2 by getting 100 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Mentor:

An expert who has written 3 tips or uploaded 2 video tips.

Joined: Aug 24, 2011
Answers
176
Questions
3
Helped
95517
Points
221

Unplug your UPS from the wall. Disconnect the batteries. Push the on button. LED's may flash. This is how to reset the logic. Connect the batteries and plug back in. Everything should be reset.

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

Lighting the LED internal fault

apc offer schematics or BOM's
there secret service manuals covers card (PCB) changes and jack names .



if not too old their official service centers can fix it;.
even out of warranty if it has recalls as many do. (smoker it.)

why be here at all and not talking to APC.com DIRECT? WHY be here.
it is their design and they made it in a factory and they do support it why not call them.? first for even ideas...
step 1 is remove batteries and test them on a bench, google how to load test UPS batteries,
I can .

now what they say on their real forum APC.com

"first off they do NOT want you inside (aside from safe battery swaps)
that is simple dead owners never buy new UPS or upgrade ever,"
case in point.
240vac is really 340volts peak and is fully lethal to humans, not Doctor Teflon man (lol)
step one is read your error logs files, using powerchute app free from them.
top fail are batteries bar none we bench test them load tested ask or google it.
step2 is log files to read. never skip this step.

yours is the older 5kw model
a tower?
and newer ones are better.
I guess you are not in the USA, (suffix "I" code )
we have EPA/DOE banning most 10 year old model here, so that is huge problem state side.
230vac line in?

https://www.apc.com/shop/my/en/products/APC-Easy-UPS-On-Line-SRV-6000VA-230V-/P-SRV6KI
0helpful
2answers

What can you advice me to do? i have a UPS SURTD5000XLI, indicating a red Led light, but when i remove it from the AC power source, the Red Led also remove & when i flog it again to the AC Source it...

Is red light on for overload or for battery?
If on overload, try reducing the load on the UPS. If red light on overload persists buy a new UPS (overload fault hard to repair).

Red light on battery - replace the batteries.

Red light on boost or buck, may mean that the nominal voltage of ups and the limits need to be changed/corrected.
0helpful
1answer
0helpful
1answer

Fault Light On

top brand UPS like this and for sure commercial grade
my UPS has 2 ways to see logs.
one is with the APP called, (free) Powerchute at Apc.com
or i use my serial console port
i login there using PUTTY at 9600,N,8,1,No flow ctrl

and type status. or type help first
this is DOS like CLI , effect with PUTTY
I type eventlog (at CLI)_
and see all logs, Esc = end, space = next page.
there is 3rd way using APC cloud but I do not have that.(overkill for home)
I have 2 connections to my UPS ,ethernet and serial console cables.
2 ways in, and is covered in the manual.
SURTD5000XLI
0helpful
1answer

SURTD5000XLI

RTM the manuals at APC.com
are all there
just read it , be brave crack a book as my dad said and USA military (all)
RTFM then.
I guess you lost the AC power cord?
just buy it like this DOA or?
i see page 2
showing how to connect it.
but the cable is not the same on all countries
things that matter are would wide and your secret not told
is power voltage there
and what connectors or connection type needed, direct wired
or plug-in and what plugs you use in your country.

manual words pg1
Configurable for 220 : 230 or 240 nominal output voltage?????
Output Frequency (sync to mains)50/60 Hz +/- 3 Hz user adjustable +/- 0.1??????

Nominal Input Voltage230V?????
XLI (the I means international version as in not for USA)
is that you 12,000- miles from USA< not told
no clues at all locations not even a country.
the manual said this day 1 new
so you did lose the the cable.

3000 VA XLI models: two output power cords,
two input power cords
page 5
Wiring must be performed by a qualified electrician.
are you, ? the first page shows connecting 1 of 2 cables supplied
the other and is done by the electrician.



cable1-undefined-undefined-0.jpg
0helpful
1answer
1helpful
1answer

UPS SURTD5000XLIQ is being powered but indicating red Led fault , What may be the cause ?

it is cause by UPS internal fault, possibilities like faulty charging circuit, inverter, etc.. you can call APC and check if its still have warranty, APC will replace it right away :D
0helpful
1answer

Apc smartups will not power up

have you check the battery, SURT UPS will not on if the battery is totally drain.
0helpful
1answer

The battrey leds stay flashing i changed battries also the led still flashing

Automatic: The UPS performs a self-test automatically when turned on, and every

two weeks thereafter (by default). During the self-test, the UPS briefly operates the

connected equipment on battery.
Manual: Press and hold the button for a few seconds to initiate the self-test

REPLACE BATTERY LED ILLUMINATES

Replace Battery LED flashes and

short beep is emitted every two

seconds to indicate the battery is

disconnected.

Check that the battery connectors are fully engaged.

Weak battery. Allow the battery to recharge for 24 hours. Then, perform a self-test. If the

problem persists after recharging, replace the battery.

Failure of a battery self-test. The UPS emits short beeps for one minute and the Replace Battery LED

illuminates. The UPS repeats the alarm every five hours. Perform the self-test

procedure after the battery has charged for 24 hours to confirm the Replace

Battery condition. The alarm stops and the LED clears if the battery passes the
self-test.

0helpful
2answers

I have a problem, when i switch on the UPS, the red "X" comes on, the first and third battery LED stays on. I opened the unit, (out of warrantee) and on the Control Panel there is a red led...

HI

IT MAY REQUIRE new battery..

p/n , battery RBC44

this UPS has
Pre-Installed SmartSlot™ Cards Ap9619, look at service manual .. see link below http://www.apcmedia.com/salestools/ASTE-6Z8LL8_R12_EN.pdf if this helped you, please rate me with 4 star
Not finding what you are looking for?

2,546 views

Ask a Question

Usually answered in minutes!

Top APC Computers & Internet Experts

Cindy Wells

Level 3 Expert

6688 Answers

Grand Canyon Tech
Grand Canyon Tech

Level 3 Expert

3867 Answers

Rob Hill
Rob Hill

Level 3 Expert

1480 Answers

Are you an APC Computer and Internet Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...