1. turn off XD125f
2. Turn on
3. within 4 seconds press, clear,
auto, clear, auto. LED Should go blank,
if not try again
4. use
copy quantity keys to enter 24, then push start
5. Again use copy
quantity keys to enter 7, then push start
6. turn off
when you
restart the cartridge count will be set to zero
I have done this
twice and never replaced the drum cartridge.
That means the drum cartridge has reached the end of its life.
You can replace the drum unit or the chip on back.
You can google a business called "the parts drop."
They should have both.
SOURCE: CLEAR J2 CODE
Hello sir; After replaced drum need to reset the counter,the procedure as follow;
1, press "clear", "Exposure","clear" "exposure" keys.
2, enter 24, press print key.
it should remove J2.