THERMISTOR OR HEATER IS ABNORMAL,PERFORM THE FOLLOWING.turn on power while pressing the clear stop button in the setting mode input 400 thn press start,change the current value 1 or 2 to 0 then press ok,turn the power off and then turn on .hope will help you vote for me my friends.
I am unfamiliar with the e-studio 18 but on other Toshiba e-studio models C41 is a fuser (hot roller) error and it will clear itself when the problem is corrected, there is no reset procedure. I would go back and be sure that the replacement was done correctly.
turn on the power while pressing clear/stop button,setting mode input 400 then press start,change current value 1 or 2 to 0 press ok.then turn off the power and back on again.i hope it will help you. please vote for me.turn on the power while pressing clear/stop button,setting mode input 400 then press start,change current value 1 or 2 to 0 press ok.then turn off the power and back on again.i hope it will help you. please vote for me.
You can't post conmments that contain an email address.
- If you need clarification, ask it in the comment box above.
- Better answers use proper spelling and grammar.
- Provide details, support with references or personal experience.
Tell us some more! Your answer needs to include more details to help people.You can't post answers that contain an email address.Please enter a valid email address.The email address entered is already associated to an account.Login to postPlease use English characters only.
Tip: The max point reward for answering a question is 15.
C41Fuser theWhat does c41 mean C41 is fuser error...u can clear it using 08-400, reset any value to "0" ...If occur again, u need to check the fuser unit, especially themistor.
All error code soloution of fuser unit Fuser Unit Error Status Counter
Purpose
When a fuser unit related error (error code C41, C43, C44 or C45) occurs, the set value of the fuser status
counter varies, depending on type of error.
Displaying and checking the set value of the fuser status counter can analyze a cause for the error. If
any of "2 to 9" is set at the fuser status counter, the fuser unit will not be operated for safety reasons.
After the fuser unit related error is resolved, if "0" is set, the fuser unit will be operated as usual. If any of
"10 to 19" is set at the fuser status counter, the fuser unit will be operated as usual, even if "0" is not set
after the fuser unit related error is resolved.
C41: Thermistor or heater abnormality at power-ON
C43: Thermistor abnormality after abnormality judgment
C44: Heater abnormality after abnormality judgment
C45: Thermistor abnormality during printing
C46 to C49: Reserved
Description
When this code is used, the current set value of the fuser status counter is displayed. Only "0" can be
manually entered, in order to restore the fuser unit to its normal operation, after the fuser unit related
error is resolved.
For further reason why the counter value differs despite the same error code, refer to 5.1.7 or 5.1.8
[Fuser unit related service call] in the Service Handbook.
0: No error 10: C47 (Reserved)
1: C41 (Once) 11: C47 (Reserved)
2: C41 (Consecutively occurs) 12: C48 (Reserved)
3: C46 (Reserved) 13: C49 (Reserved)
4: C43 14: C47 (Reserved)
5: C44 15: C48 (Reserved)
6: C45 16: C49 (Reserved)
7: C44 17: C47 (Reserved)
8: C45 18: C48 (Reserved)
9: C44 19: C49 (Reserved)
* Default: 0
Setting Timing
Use this code to resolve the fuser unit related error (error code C41, C43, C44 or C45). Resolve the
error, and set "0" (or reset the counter), in order to restore the fuser unit to its normal operation.
Caution
Remember to resolve the fuser unit related error, and then reset to "0." also 447
All error code soloution of fuser unit Fuser Unit Error Status Counter
Purpose
When a fuser unit related error (error code C41, C43, C44 or C45) occurs, the set value of the fuser status
counter varies, depending on type of error.
Displaying and checking the set value of the fuser status counter can analyze a cause for the error. If
any of "2 to 9" is set at the fuser status counter, the fuser unit will not be operated for safety reasons.
After the fuser unit related error is resolved, if "0" is set, the fuser unit will be operated as usual. If any of
"10 to 19" is set at the fuser status counter, the fuser unit will be operated as usual, even if "0" is not set
after the fuser unit related error is resolved.
C41: Thermistor or heater abnormality at power-ON
C43: Thermistor abnormality after abnormality judgment
C44: Heater abnormality after abnormality judgment
C45: Thermistor abnormality during printing
C46 to C49: Reserved
Description
When this code is used, the current set value of the fuser status counter is displayed. Only "0" can be
manually entered, in order to restore the fuser unit to its normal operation, after the fuser unit related
error is resolved.
For further reason why the counter value differs despite the same error code, refer to 5.1.7 or 5.1.8
[Fuser unit related service call] in the Service Handbook.
0: No error 10: C47 (Reserved)
1: C41 (Once) 11: C47 (Reserved)
2: C41 (Consecutively occurs) 12: C48 (Reserved)
3: C46 (Reserved) 13: C49 (Reserved)
4: C43 14: C47 (Reserved)
5: C44 15: C48 (Reserved)
6: C45 16: C49 (Reserved)
7: C44 17: C47 (Reserved)
8: C45 18: C48 (Reserved)
9: C44 19: C49 (Reserved)
* Default: 0
Setting Timing
Use this code to resolve the fuser unit related error (error code C41, C43, C44 or C45). Resolve the
error, and set "0" (or reset the counter), in order to restore the fuser unit to its normal operation.
Caution
Remember to resolve the fuser unit related error, and then reset to "0."
All error code soloution of fuser unit Fuser Unit Error Status Counter
Purpose
When a fuser unit related error (error code C41, C43, C44 or C45) occurs, the set value of the fuser status
counter varies, depending on type of error.
Displaying and checking the set value of the fuser status counter can analyze a cause for the error. If
any of "2 to 9" is set at the fuser status counter, the fuser unit will not be operated for safety reasons.
After the fuser unit related error is resolved, if "0" is set, the fuser unit will be operated as usual. If any of
"10 to 19" is set at the fuser status counter, the fuser unit will be operated as usual, even if "0" is not set
after the fuser unit related error is resolved.
C41: Thermistor or heater abnormality at power-ON
C43: Thermistor abnormality after abnormality judgment
C44: Heater abnormality after abnormality judgment
C45: Thermistor abnormality during printing
C46 to C49: Reserved
Description
When this code is used, the current set value of the fuser status counter is displayed. Only "0" can be
manually entered, in order to restore the fuser unit to its normal operation, after the fuser unit related
error is resolved.
For further reason why the counter value differs despite the same error code, refer to 5.1.7 or 5.1.8
[Fuser unit related service call] in the Service Handbook.
0: No error 10: C47 (Reserved)
1: C41 (Once) 11: C47 (Reserved)
2: C41 (Consecutively occurs) 12: C48 (Reserved)
3: C46 (Reserved) 13: C49 (Reserved)
4: C43 14: C47 (Reserved)
5: C44 15: C48 (Reserved)
6: C45 16: C49 (Reserved)
7: C44 17: C47 (Reserved)
8: C45 18: C48 (Reserved)
9: C44 19: C49 (Reserved)
* Default: 0
Setting Timing
Use this code to resolve the fuser unit related error (error code C41, C43, C44 or C45). Resolve the
error, and set "0" (or reset the counter), in order to restore the fuser unit to its normal operation.
Caution
Remember to resolve the fuser unit related error, and then reset to "0."
All error code soloution of fuser unit Fuser Unit Error Status Counter Purpose When a fuser unit related error (error code C41, C43, C44 or C45) occurs, the set value of the fuser status counter varies, depending on type of error. Displaying and checking the set value of the fuser status counter can analyze a cause for the error. If any of "2 to 9" is set at the fuser status counter, the fuser unit will not be operated for safety reasons. After the fuser unit related error is resolved, if "0" is set, the fuser unit will be operated as usual. If any of "10 to 19" is set at the fuser status counter, the fuser unit will be operated as usual, even if "0" is not set after the fuser unit related error is resolved. C41: Thermistor or heater abnormality at power-ON C43: Thermistor abnormality after abnormality judgment C44: Heater abnormality after abnormality judgment C45: Thermistor abnormality during printing C46 to C49: Reserved Description When this code is used, the current set value of the fuser status counter is displayed. Only "0" can be manually entered, in order to restore the fuser unit to its normal operation, after the fuser unit related error is resolved. For further reason why the counter value differs despite the same error code, refer to 5.1.7 or 5.1.8 [Fuser unit related service call] in the Service Handbook. 0: No error 10: C47 (Reserved) 1: C41 (Once) 11: C47 (Reserved) 2: C41 (Consecutively occurs) 12: C48 (Reserved) 3: C46 (Reserved) 13: C49 (Reserved) 4: C43 14: C47 (Reserved) 5: C44 15: C48 (Reserved) 6: C45 16: C49 (Reserved) 7: C44 17: C47 (Reserved) 8: C45 18: C48 (Reserved) 9: C44 19: C49 (Reserved) * Default: 0 Setting Timing Use this code to resolve the fuser unit related error (error code C41, C43, C44 or C45). Resolve the error, and set "0" (or reset the counter), in order to restore the fuser unit to its normal operation. Caution Remember to resolve the fuser unit related error, and then reset to "0."
with the power off,hold down the "0"&"8" keys while you turn the power on.Then enter the code 400 and change the number showing to a "0". That will reset the error code.
×