Haier (HBF05EAVS) Beverage Dispenser Logo

Related Topics:

A
Anonymous Posted on Sep 14, 2012

It's not cooling my kegerator

My Haier kegerator is not cooling anymore. The compressor runs and it gets very hot because it's not cooling anymore.

3 Related Answers

Anonymous

  • 76 Answers
  • Posted on Sep 11, 2008

SOURCE: I have a Haier HVFM20ABB

If the motor still runs its a gas problem.
You need to get a re gas done on your fridge...

Later...

Wouter...

Ad
TheMobilian

Dan Webster

  • 8221 Answers
  • Posted on Jun 04, 2010

SOURCE: Haier refrigerator is not cooling and compressor

If the compressor has a relay chances are it is toast.

If you need further help, reach me via phone at https://www.6ya.com/expert/dan_73bbd84fe1d95b61

Anonymous

  • 10 Answers
  • Posted on Aug 08, 2011

SOURCE: Haier model HRQ04WNAWW refrigerator.

the compressor has an internal overlod inside of it after 115 degress it opens and wont start till it cools down below 115 unplug and try putting ice cubes on top of com pessor to cool it down otherwise it will take hours to cool off

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
2answers

Why no cold air coming out of a.c. maker is HAIER

Did you check to see if the compressor is running? If not, check the start relay/capacitor.
0helpful
1answer

TDD 2 Kegerator clicking and not cooling?

It's extremely rare that the compressor will be any good. Usually replacing the start relay does nothing on these small units. If you know how to use a multi-meter and are any good at wiring the cheapest way to go is to get what is called a 3-in-1 start kit at a HVAC wholesaler. You need to know the model of the compressor and/or the horsepower to get the right one. I would recommend getting a service tech to look it over though. Most likely the compressor is locked up.
1helpful
1answer

Danby Kegerator runs but does not Cool

sounds like maybe no coolant in system if compressor is working. you know like in your car a/c unit, sometimes refrigerant needs to be added. just a guess, I'm not an expert.
0helpful
1answer

Compressor seems bad

HI sally.well wine coolers r not rocket science.your local engineer should be able to at least diagnose the problem...lets c if u can do it ok?(still getting power )u mean light comes on or u mean it runs but dont get cold?well haier is not the best but if it's done 7 years is not bad:).ok...1-check if it makes any noise or is completely quiet.if no sound feel the motor (compressor).hot or cold.if cold it could be the thermostat or motor.if hot running or not it could be refrigerant or motor.needs visual.hope this helps.ALI
0helpful
2answers

Haier model HRQ04WNAWW refrigerator. Stopped cooling suddenly. Compressor is hot, really hot, and doesn't make a sound. Light is still on inside of unit, so are getting power.

the compressor has an internal overlod inside of it after 115 degress it opens and wont start till it cools down below 115 unplug and try putting ice cubes on top of com pessor to cool it down otherwise it will take hours to cool off
3helpful
1answer

Haier Mini spilt HSU18VC7 compressor runs for 5 minutes then stop 3 minutes then run another 5 minutes and so on.

This is called short cycling. It sounds like the compressor is getting hot and opening a bi-metal overload, which shuts the compressor off. The compressor cools, because it is not running and the bi-metal contacts close allowing the compressor to start again. This will repeat itself and is usually due to low refrigerant, which usually means there is a leak in the normally sealed refrigerant lines. The refrigerant cools the compressor windings and if it is low it cannot do that, hence the shutting off of teh compressor, cooling down process and restarting of your compressor. Short cycling will ultimately ruin the compressor.

If this has helped you please give me a rating worthy of my diagnosis.
0helpful
1answer

Compressor kicks on, but unit does not cool

refrigerators dont come with shrader valves. U must buy a clamp on or weld one on the low side. The clampons are not expensive and are called Bullet piercing valve BPV 31 and fit 3 sizes. Unfortunately u also have a leak somewhere. Most refrigerators use either R12 or 134a

If you need further help, reach me via phone at https://www.6ya.com/expert/gary_9c859f4aa7e5ab10

0helpful
1answer

Haier model hslorwnawn refrigerator/freezer neither one gets cold or freezes.

Could be a compressor or refrigerant charge problem. Check to see if the compressor is hot. If so is it running. If not and it is hot the compressor is the problem. If the compressor is cold it is in the power supply to the compressor. That would be the thermostat or defrost timer. If the compressor is running and it is not cooling it could be the refrigerant.
Not finding what you are looking for?

98 views

Ask a Question

Usually answered in minutes!

Top Haier Refrigerators Experts

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66975 Answers

vince

Level 3 Expert

2530 Answers

Brad Brown

Level 3 Expert

19187 Answers

Are you a Haier Refrigerator Expert? Answer questions, earn points and help others