...operating pressure on low side and on the high side for truee freezer using 404 refrigerant I'll try to give you the "Readers Digest" version. First, make sure there is no ice build up on the evap. ...
Question about Freezers
...404A refrigerant Generally, low side is around 20-25 PSI and High side is about 235-250 when unit is close to operating temp. Expansion device effects this to some degree such as a cap tube can ...
...like the normal operateing pressures in a 70* space with a box temp of 10* this is a 404a unit http://www.totaline.com.ar/site/uploads/file_7-200652412174-0.pdf Here is a PTC with all of the
...operating pressures i have a victory 2 door freezer. r-404a freon, cap tube system.what is normal pressures thanx steve Normal operating pressures will change as the freezer reaches the selected ...
...Operating pressure for true 2 door Freezer R404A Room Under 80 degrees F Box at -10 degrees F The pressures depend, somewhat, on the expansion device,i.e. a TXV or Cap Tube. Take a pressure reading, ...
...model t-23f not freezing whats the problerm and what to operation pressure for this model. (using 404A freon) Depends on how technical you want to get. Generally, measure the ambient temp of air ...
...404a , cro valve replaced,drier replaced system flushed with rx11. System appears to be operating good brings unit down to -15 . amp draw 7.2 restarts great cro valve working. my problem is suction ...
...404a. is there any rule of thumb to make it easy to remember those important parameters or formula in refrigeration. why yes there is. Generally speaking, the head pressure should be around the ...
...404a the head preasure risies to over 400 psi i think it is the txv advise me if i am right There are a lot of variables that cause high head pressure. Be sure the cool ing fan is operating properly. ...
404a operating pressures What is your question?
4 questions posted
Usually answered in minutes!
1 Questions
1 Questions