Question about Electrical Supplies

1 Answer

circuit breaker.each time l switch on the circuit breaker trips out,thought it was overload single phasing,so remove overload from circuit and wired motor direct to contactor,but still tripping out at

Ad

circuit breaker for a Bryant panel. It won't fit all the way in because the rails it fits onto are deep. Can the two metal pieces blocking the slots on the new breaker be removed so it will push fully

Ad

Question about New 20 Amp Tandem A2020n A Circuit Breaker

1 Answer

how to determine if the breaker fits left or right side If this is a regular household breaker box then the breaker should work on either side.

Question about 15 Amp Murray Afci Circuit Breaker

1 Answer

breaker to see if it will fit your panel (probably not) Murry is now Siemens I believe, and Cuttler Hammer is Eaton. There was a Murry-Cuttler Hammer-Challenger connection for awhile, but just because

Question about Circuit Breaker

1 Answer

...are rated at 80% of their rating for continuous loads. So if you installed a 60 amp circuit, 80% of 60 = 48 amps. This would fit your requirement. That would be a 60amp breaker, with #6 cu

Question about D Circuit Breaker Load Center Q0112m100 Ser S01

1 Answer

...circuit breaker that fits into a Square D Homeline Load Center - it is not available locally - what other manufacturer's 15A GFI circuit breaker fits into a Square D Homeline Load Center? That number ...

Question about Q1515NC Circuit Breaker Two1Poles 15Amp no clip

1 Answer

...circuit. Will a Q1515NC fit into one of the Q115 slots? Yes they will fit. They are both a single pole breaker. Turn the breakers over. They should look the same and snap into a single slot in the ...

Question about Circuit Breaker Kit for Furnace

1 Answer

circuit breaker doesn't fit - then something is wrong. Typically, circuits are designed around the amount of voltage and current a product requires. The voltage determines the combination of material

Question about D Co. HOM130C Circuit Breaker

1 Answer

...circuit breaker fit into a ITE PANEL to replace a 20 a circuit breaker? Use siemens for old ITE breaker box. Square D will not work: http://waterheatertimer.org/See-inside-main-breaker-box.html Add a ...

...circuit breaker for power windows on a 2000 VW jetta? there's is no circuit breaker in a car, but there's is fuse distribution box in the engine compartment Electric windows didn't use to have a ...

Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top Electrical Supplies Experts

Brad Brown

Level 3 Expert

19187 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66971 Answers

CJ Rock
CJ Rock

Level 3 Expert

4429 Answers

Are you an Electrical Supplies Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...