Anonymous Posted on Jun 26, 2010

Had heat pump replaced roughly a month agoworked fine until yesterday.the wife says it was 85 degrees on the thermostst when it was set at 78. Told her to check breakerfreon line at air handler and compressor;breaker was good line was not cold or condensating said fan was on but not compressornothing was frozen.told her to turn thermo to off till it cools down.this am said it was cool then it wasn'tnow it is.this is a 3 ton 13 seer r-12 unit...thx rob

1 Answer

Anonymous

Level 2:

An expert who has achieved level 2 by getting 100 points

Hot-Shot:

An expert who has answered 20 questions.

Corporal:

An expert that has over 10 points.

Mayor:

An expert whose answer got voted for 2 times.

  • Expert 74 Answers
  • Posted on Jun 26, 2010
Anonymous
Expert
Level 2:

An expert who has achieved level 2 by getting 100 points

Hot-Shot:

An expert who has answered 20 questions.

Corporal:

An expert that has over 10 points.

Mayor:

An expert whose answer got voted for 2 times.

Joined: Aug 27, 2009
Answers
74
Questions
1
Helped
20093
Points
132

Call the install company back out. along with the new heat pump i wouls say they installed a leak. you stated r12 i assume you ment r22 if they installed an r22 unit and didnt change the a coil it might not be their work leaking but the a coil might be. at any rate once you have them fix it i would look for a new service company i would never install an r22 system any more the EPA is phasing it out and the replacment in my opion is beter

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

I have a Braeburn 3200 and when the the temperature reaches the desired heat setting. The furnaces heat will shut off, but the fan will continue to run indefinetly. eventually blowing very cold air up

The fan relay is stuck in the on position. When the temperature drops the heater does not ignite because the fan is already running and ignition is locked out after the heat cycle starts an the fan turns on
0helpful
1answer

My grandchildren played with my thermostat yesterday and unfortunately I can’t get it to where I’ve had it for the last 6 yrs. I have it set at 70 degrees and it elevates after 1 hr or 2 to 78 on the...

Your thermostat should have a hold feature indicated by "hold" on or near the hold button. Once this button is pressed "hold" should be indicated somewhere on the screen. When the hold feature is activated your thermostat should stay at the given set-point indefinitely.
If you would like to use the program feature of your thermostat I need to know the make and model before I can help you.
1helpful
1answer

I am working on a M # GPG13420901AB. This is a 3.5 ton package unit that replaced a 3 ton package unit on 1700sq/ft single level home. Old unit was working fine but was replaced when the home was...

It sounds like you are low on charge. I think you have a thermostatic expansion valve and you need to check the subcooling, you should have 12 to 15 degrees at 95. At 95 degrees your head should be about 280# for a 12 or 13 SEER unit or higher depending on the effeciency. At 78 to 80 degrees indoor depending on the humidity, that is normal. The valve will open to try to fully feed your indoor coil and it sounds like your head pressure is to low to force enough refrigerant thru the coil.
0helpful
1answer

What tempratues should be set on a honywell 4 cycle thermost during the summer months

As a general rule set your t.sat 20 degrees below outside temp. Leave at this setting 30-45 minutes. Move down until comfortable no lower than 10 degrees below outside for 30-45 minutes. Unit should cycle normally. If it runs continuously then raise the t.stat 3 or 4 degrees up. The national average is 75-78. I usually keep mine set at 80 during the day here in Georgia and 74-78 at night...
Not finding what you are looking for?

173 views

Ask a Question

Usually answered in minutes!

Top Goodman Heating & Cooling Experts

Paul Carew

Level 3 Expert

3808 Answers

Mike Cairns
Mike Cairns

Level 3 Expert

3054 Answers

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

Are you a Goodman Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...