So you need another bulb correct To order replacement lamps directly from The Sharper Image, call 1-800-344-5555 and order item number SI922. Lamps are effective for about 12 months of continuous use.
G15T8 15W 15 Watt UV Germicidal Bulb IONIC BREEZE GP this bulb is available on ebay for under $11.00. The release tab for the cover is at the bottom of the cover and it comes off pretty easy. Once the cover is off you turn the lamp 1/4 turn (two clicks) and slide it from it's fixture.
G15T8 15W 15 Watt UV Germicidal Bulb IONIC BREEZE GP Item number on ebay is: 220444965077
$10.99 plus around $5 to ship.
Pull up on the tab on the bottom of the front filter and pull up. You then should be looking at the bulb, which you will turn 1/4 turn (2 clicks). You should then be able to pull the bulb out.
This is a repair that someone I know didafter reading a post on the net.....regarding Quadra repairs....and here is a link for repairs....its all one link....so type it into your browser or paste it.....
Gently remove the top as there are wires connected to it.
Once removed, find the microswitch assembly on the side. There will be 2 green wires going to this assy board (PCB).
Examine the bottom of this board. On both my units, the PCB wascorroded badly on the trace that runs from the center lead to the wireconnection. This will cause the microswitch to quit working.
What I did was soldered a wire from the center contact of themicroswitch (center piece coming through the board. There should be alarge solder pool) to the wire connection at the edge of the board.This just 'goes around' the corroded PCB trace.
Worked fantastic on both ionic breezes and took about 5 minutes for thesecond one. The first one took over 2 hours just to find the problem.
I hope this helps.....good luck...thanks for rating my effort....the Fang.
My professional series Ionic breeze GP blows out what seems to be clean air but the purple lights inside it are no longer working. Can anyone tell me where I can find replacement bulbs or just what I need to do to get it working again. I got it as a gift 4 or so years ago. The gift giver says there was a 5 year warranty on it but I am not sure. Any advice would be helpful.
×