This is a repair that someone I know didafter reading a post on the net.....regarding Quadra repairs....and here is a link for repairs....its all one link....so type it into your browser or paste it.....

http://www.airpurifierrepair.com/ProductDetails.aspx?ID=34&ProductId=591


Remove the grid assembly.

Remove the 4 screws holding the top on.

Gently remove the top as there are wires connected to it.

Once removed, find the microswitch assembly on the side. There will be 2 green wires going to this assy board (PCB).

Examine the bottom of this board. On both my units, the PCB wascorroded badly on the trace that runs from the center lead to the wireconnection. This will cause the microswitch to quit working.

What I did was soldered a wire from the center contact of themicroswitch (center piece coming through the board. There should be alarge solder pool) to the wire connection at the edge of the board.This just 'goes around' the corroded PCB trace.

Worked fantastic on both ionic breezes and took about 5 minutes for thesecond one. The first one took over 2 hours just to find the problem.

I hope this helps.....good luck...thanks for rating my effort....the Fang.

Sharper Image... | Answered on Jul 14, 2019


yes there is a fuse on the board located at the base of the unit...if that does not fix problem replace unit.. :)

I’m happy to help further over the phone at https://www.6ya.com/expert/jovani_c02b023fe087f6cd

Sharper Image... | Answered on Nov 16, 2015


It means that the unit needs to be cleaned.

Sharper Image... | Answered on Aug 07, 2014


It means that the corona wires require cleaning in order for the ionic filtration to again begin working (it is not filtering when the light is on).

Sharper Image... | Answered on Jul 09, 2014


I have replaced those wires with chrome plated wire, stainless steel wires and platinum wires. Nothing lasts very long (weeks to a few months). There are no parts available for these machines as far as I know.

Charlie

Sharper Image... | Answered on Jun 15, 2014


well i had the same problem at one time ..heres what to do... try turning it upside down and bang on the unit gently .not to break it and make sure you did not break the two strings behind the vents..
take out the bulb and clean the whole inside as best as you can..
and if that wont work unplug turn button to on pisitioin and then plug the unit inand hope for the best ... if all else fails go to amazon and replace the unit..hope that helps

I’m happy to help further over the phone at https://www.6ya.com/expert/jovani_c02b023fe087f6cd

Sharper Image... | Answered on Jun 11, 2014


You can go right to the Sharper Image site and get manuals there. Just find your model, and towards the bottom of the description you'll find links to the manuals, Try this one http://www.sharperimage.com/pdf/Electrostatic-Air-Purifierc.pdf

Sharper Image... | Answered on Apr 20, 2014

Not finding what you are looking for?
Sharper Image Ionic Breeze GP SI730 Air Purifier Logo

148 questions posted

Ask a Question

Usually answered in minutes!

Top Sharper Image Air Purifiers Experts

Ekse

Level 3 Expert

13434 Answers

Marvin
Marvin

Level 3 Expert

85231 Answers

Cindy Wells

Level 3 Expert

6082 Answers

Are you a Sharper Image Air Purifier Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Sharper Image Air Purifiers

  • Sharper Image Air Purifiers

Most Popular Question

broken wire inside ionic breeze

  • Air Purifiers
Loading...