The oil in a refrigerator is contained in the coolant lines and they are sealed. No oil can leak out if the lines are intact. That has to be something else.
Hi,
After cleaning out the machine, please double check that it's not attempting to cool any object that's extremely hot. Also, you might want to switch power outlets and test the cooling again. Then if still not working, you can use the troubleshooting section of the manual to help overcome the issue. Thank you.
Question moved from Garden category.
Dimensions ยท H 59.4 in, W 23.6 in, D 25.2 in ; Appliance Type, Compact Refrigerator ; Color - Appliance Cabinet, White ; Color - Door Handle(s), White ; Color/Finish
It sounds like the icemaker had a dead short and tripped the breaker. You would have to strip it down and check all the electrical components and look for water leaks onto electrics.
Either condensation or a crack in the ice bin is the most likely, but it could also be a lack of cleaning / descaling and that water is spraying inside and finding its way outside of the case.
I have had a career dealing with icemaker issues. :>)
same problem w mine and yes if you take the cover off the inside display you will be able to remove the board mine has a hole burnt in it.unplug harness w red blue and brown wires and jump and jump from brown to red unit will turn on you need a new board
As it is brand new you should not be fiddling with it as it is likely to invalidate the warranty - if it doesn't work as it should you should immediately call the supplier, which is who your contract is with.
Could be the manufacturer forgot to add lubricant and the compressor seized or perhaps the motor start winding is damaged - whatever the problem is, it shouldn't be yours.
Fridge not starting?CLICKING? FIRSTALWAYSCHECK FORpower at the outlet,checkfor 120 volts.
MAY HAVE A BAD START RELAY OR CAPACITOR ONTHE COMPRESSOR , CAN BUY A INEXSPENSIVE 3 IN 1 HARDSTART KIT AND BY PASS THEM , NOT THAT HARD TO DO, COMES WITH INSTRUCTIONS> ? BY THE WAY DO U HEAR ANY CLICKING SOUNDS FROM COMPRESSOR? BUT U MAY ALSO WANT TO CHECKURCOLD CONTROL THERMOSTAT IF IT GOES BAD U MAY GET A NON START ALSO HAVE IT CHECKED FOR PROPER VOLTAGE AND OHMS RESISTANCE WHEN IN THE ON POSITION
A BAD DEFROST TIMER though seldom CAN SHUT DOWN COMPRESSOR HAVE IT CHECKED WITH MULTI METER.
to check thedefrost timer, u can get by and test manually by placing a small screw driver into the tiny slot or hole underneath the timer and turn slowly clockwise till u hear 1 click. this will engageurdefrost cycle in about 15 minutes u should be able to come back and feel the heat in freezer as it melts the ice providingurterminator is not bad?
Another way to test it is with a multi meter. Remove timer it from fridge and you will see 4 prongs numbered 2,1,4,3 in that order. Placeurmeter prong on prong 1 & 3 (if your fridge has a capacitor wired in series with the windings, then u check for micro fares rather than OHMS) If u cannot confirm this test, still try the next.
Takeurmeter prong and connect to prong 1 & 4, it should read resistance or ohms ( closed) now remove prongs and place on prong 1 & 2, this should now read infinity or open (no ohms) now take a small screwdriver place it in the tiny hole or slot under the timer. Turn it clockwise slowly till u hear 1 click.
Nowur1& 2 should read closed ( showing ohms or resistance) now place meter prongs on 1 & 4 and you it should now show open ( or no resistance - no ohms) this is how u knowurtimer is good, Remember when testing for ohms ADJUST meter to use a high ohms rating in the thousands as the resistance is very high in OHMS.
And adjusting to low ohms rating may give a false reading or not show the proper resistance..
Some fridges are now using ADC boards.
Designers are using microprocessors (on solid state circuit boards) to adapt defrost intervals and durations to compensate for differences and changes in operating conditions. Such techniques are calledAdaptive Defrost Control, commonly abbreviated as ADC.Theyare normally found in same locations as the timer would be but look somewhat different in appearance. It is more difficult to test these units without the appliance schematic.
Some ADC / control boards control other functions of the refrigerator, too, such asicemakingand electrical air damper door opening andclosing.Thedefrost frequency may also be shortened under certain circumstances.
AT TIMES YOU MAY HEAR THE COMPRESSOR CLICK OFF AND ON OVER AND OVER. Signs of a bad start relay or capacitor.Check with an OHMS meterfor continuity (ohms) and voltage, capacitor can be checked forMicrofares.( if in series with the windings)
If you hear your compressor "short-cycling" (starting and stopping at short intervals) try jumping across the two leads of the cold controlthermostat ( in the fridge compartment)with an alligator jumper.You can also check both for live voltage current and ohms-If there is a greenthirdlead, ignore it for this test; it is the ground wire. If the fridge starts running constantly, the cold control is bad. Replace it.
To checkurcompressor with multi meter:
Disconnect and remove the relay and capacitor from compressor, sometimes located next to compressor in a casing.
You wills see 3 prongs coming out of compressor. 1 goes tourstart winding, 1 goes tourrun winding and the center goes tourground or COM
Placeurmeter connector or prong on the start prong and the other on the ground (center prong) take note of the reading in OHMS for example 5 ohms.
Next place meter prong on run prong and the center ground prongagin. Take note of the reading in OHMS. Example 4 ohms
Next place meter prong on the start prong and the other on the run prong, now take note of the reading example 9 ohms. Now match the total of this ohms test with the total ofurtwo separate test. 9 ohms, if they matchurok give or take 5 percent plus or minus. One more test to make to test of there is a short in compressor attach meter prong to ground prong and rub the other end of meter prong to metal ( scrape the metal clean of paint and test on metal surface not painted surface. If it shows continuity or ohms, u have a short inurcompressor. It should show infinity
God is so good: so this is why I give free advice so please thank him not me.
TO REPLACE RELAY AND CAPACITOR WITH A HARDSTART KIT YOU CAN USE
A3 in 1 start kit for compressors sizes 1/4 through 1/3 HP. And a 5 in 1 for higher H.P. (BE SURE TO MATCH WITH UR COMPRESSOR MODEL NUMBER AND TYPE) Thekit includes relay, capacitor, andoverload device, pre-wired. Thekit will replace all 3 electrical components on capillary refrigeration systems. For newer systems with a run capacitor use?proper kit. For smaller horsepower compressors useTJ90RCO810.
The wire set up is as follows the red wire goes to the right side of compressor prong, the white wire to the left side prong, the black wire to the center prong, and the 2 other black wires go to the power and the ground connection
http://www.appliancerepair.net/refrigerator-repair-1.html
https://www.youtube.com/watch?v=-L80Fk5had4 defrost timer