Rheem RTG-74PVN-2 Natural Gas Pronto Whole House, Natural Gas, Tankless Wat Logo
Phillip Hornsby Posted on Jan 14, 2011
Answered by a Fixya Expert

Trustworthy Expert Solutions

At Fixya.com, our trusted experts are meticulously vetted and possess extensive experience in their respective fields. Backed by a community of knowledgeable professionals, our platform ensures that the solutions provided are thoroughly researched and validated.

View Our Top Experts

Rheem rtg-74pvn2 will heat for a couple minutes, then, shuts off and flashes C8 76 on remote controller. I have insured good connections on both ends of cable, even replaced cable, same problem.

1 Answer

Anonymous

Level 2:

An expert who has achieved level 2 by getting 100 points

MVP:

An expert that got 5 achievements.

Governor:

An expert whose answer got voted for 20 times.

New Friend:

An expert that has 1 follower.

  • Expert 126 Answers
  • Posted on Jan 14, 2011
Anonymous
Expert
Level 2:

An expert who has achieved level 2 by getting 100 points

MVP:

An expert that got 5 achievements.

Governor:

An expert whose answer got voted for 20 times.

New Friend:

An expert that has 1 follower.

Joined: Mar 16, 2010
Answers
126
Questions
0
Helped
54028
Points
242

Could be a vent problem,check out side

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

Rheem rtg-66dv error code 12

Troubleshoot and error codes following link:
http://waterheatertimer.org/pdf/RTG-error-codes-3.pdf

Not getting gas, low gas pressure, air in gas line, igniter not aligned with burner, wires disconnected, unit not grounded ...

If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7

3helpful
1answer

I have sign C7 76 and the unit shuts off. What is wrong?

Sorry to read about your problem, I hope this helps you out.
Your code 76

Communication Fault with Remote Control
Check remote control wiring for loose or damaged connections. Bypass remote control cable by connecting remote control directly to remote control terminals on PCB. Replace cable if found to be faulty. Replace remote control. Replace PC

I tried to help you. Please help me and Rate/Vote on my response, thanks and good luck
2helpful
2answers

I have a Rheem tanklees water heater, model RTG-74XN-2. The remote shows the following error code. C4 then the number 76 then C4 then 76. What does this code mean??

Contact Paloma/Rheem 866-720-2076. Super nice! I just called regarding mine. Having same problem Rheem Paloma sending parts out tomorrow overnite. Try turn it on/ off by moving tiny switch under the unit that tells you the temperature. Run your fingers along the bottom to find it. That is a temporary fix. Below is a website with all the error codes, so you know what is wrong. Good luck and blessings!

http://www.palomastore.com/paloma_error_codes.html

76
Communication Fault with Remote Control Check remote control wiring for loose or damaged connections. Bypass remote control cable by connection remote directly to remote control terminals on PCB (replace cable if found to be faulty). Replace remote control. Replace PCB

76
Communication Fault with Remote Control Check remote control wiring for loose or damaged connections. Bypass remote control cable by connection remote directly to remote control terminals on PCB (replace cable if found to be faulty). Replace remote control. Replace PCB

76
Communication Fault with Remote Control Check remote control wiring for loose or damaged connections. Bypass remote control cable by connection remote directly to remote control terminals on PCB (replace cable if found to be faulty). Replace remote control. Replace PCB

76
Communication Fault with Remote Control Check remote control wiring for loose or damaged connections. Bypass remote control cable by connection remote directly to remote control terminals on PCB (replace cable if found to be faulty). Replace remote control. Replace PCB

0helpful
1answer

Rheem tankless rtg 74pvn - heater hot water shuts

This is something you will have to contact rheem about due to the fact you don't have a fault code
2helpful
1answer

Unit kicks off indicates C-2 and 11 . I go through the restarting process, it starts and then kicks off immediately and control starts flashing the C-2 and then 11. mod. # RTG-74PVN2

I had that happened twice to me by now.
Turns out to be dirty burner unit.

I got a "removal cleaning reinstallation" bulletin for the model 74 that I went by.
I basically took the burner unit apart cleaned it out (compressed air) and put it together again.
That did it.

johenkel
2helpful
3answers

Hi, I have a Rheem RTG-74PVN-2 tankless hot water heater. It has run great for about a year, but now shuts off completely after running for approx. 8-10 minutes. I have the water temp set at 130 f. Any...

Remove power source from the unit. If remote control is installed; remove cover and lift the control wires on the terminal...can be accomplished from either end. See if the unit runs longer.
If you're receiving any error codes, especialy code 76; contact RHeem customer support at (800-432-8373) and notify them IF you are getting a code "76" error.

Good luck,
JZ...
3helpful
2answers

Rheem Tankless wh model rtg-74pvn shuts off error code c4 76

Contact Rheem; the Burner control unit has lost comm with the remote...the part is warranteed for up to five years.
3helpful
1answer

Rheem RTG-74PVN-1 Water heats for abot 2 minutes

overheat stat or fan, on fan check for small pinhole in rubber tube best of luck
5helpful
1answer

My Rheem Pronto model#RTG-74PNV-1 has powered off for some reason unknown, I turned the unit back on and it supplied hot water for approx. 10 minutes before it started flashing a code [C7]on the remote...

Remove power source from the unit. If remote control2.gif is installed; remove cover and lift the control wires on the terminal...can be accomplished from either end.

Restore power and see if unit functions normally.

Contact Paloma/Rheem customer (800-432-8373) support and notify them IF you are getting a code "76" error. Rheem has recently extended the warranty on the "Burner Control Assm."; which is your problem. The C4-C8 portion of the error code, is where the unit stops the ignition process...burner fails to light, or gives you intermittent hot water. In either case, contact customer support2.gif.

If this helps, please indicate so.
Mike//[email protected]
3helpful
1answer

Heater shuts down with C4-13 code

your not getting enough fresh air to it. where is it located? you need 1 square inch per 1000 btu's. it's having irregular combusion.
Not finding what you are looking for?

211 views

Ask a Question

Usually answered in minutes!

Top Rheem Water Heaters Experts

Mike Cairns
Mike Cairns

Level 3 Expert

3054 Answers

Brad Brown

Level 3 Expert

19187 Answers

Sean Wright
Sean Wright

Level 3 Expert

2045 Answers

Are you a Rheem Water Heater Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...