Our boiler element will not shut off after a while the F1 code appears on the display but the element still won't shut off. We have had to shut off the breaker to shut the range off.

1 Answer

Anonymous

Level 2:

An expert who has achieved level 2 by getting 100 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Vice President:

An expert whose answer got voted for 100 times.

  • Expert 189 Answers
  • Posted on Mar 03, 2010
Anonymous
Expert
Level 2:

An expert who has achieved level 2 by getting 100 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Vice President:

An expert whose answer got voted for 100 times.

Joined: Jan 28, 2010
Answers
189
Questions
1
Helped
51616
Points
539

Hello- Bad news- The Elec control is fried. F-1 is the main fault code. A circuit has fused causing power to flow to to broil element. Board is about 150$. Have a tech check all wiring when installing replacement. Electric ovens put in 'self- clean' will eventually burn out the control. Avoid this 'function'. Let me know if this info helps- have more if needed. Thanks- ED

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

Why is my oven not working?

Kenmore oven model 790 error code f1
The F1 error code in most of the Kenmore 790 models means the control is not sensing the temperature properly. The tech sheet advises us to disconnect power for 30 to 60 seconds, and after power is reapplied if F1 is still present, replace the EOC (Electronic Oven Control).Mar. 15, 2010

How do I fix an F1 error for my Kenmore 790 self-cleaning oven?

..
0helpful
1answer

Error code list

ALARMS THAT STOP THE DISHWASHER

A1 Want of water

Is the water cock open?

Does the water load solenoid valve work?

Is the water feed flow a min. of 5 l/min?

Is the water inlet filter clean?

Is the load solenoid valve filter clean?

Is the overflow inserted?

Do the tank/boiler pressure switches work properly?



C9 Automatic hood out of order

Alarm codes for automatic hood type dishwasher (see paragraph 9.2.1 Alarm codes for automatic

hood type dishwashers)



C12 Tank level sensor out of order

Are the connectors correctly connected?

Are connector contacts cleaned?

Does the air trap of the tank work correctly?

Is the level sensor broken (replace it with a new one)?



Alarm codes for automatic hood type dishwashers

When the alarm C9 appears, to facilitate fault-finding a parameter providing a more detailed indication has

been introduced.

The parameter is C9 and is found in the ron family.

The possible cause of the anomaly can be found (see next table) according to the value of the parameter C9.

E.g.: With an automatic hood type the alarm C9 appears.

Access the parameter C9 in the ron family.

Assuming the value displayed is:

20 ? During lifting, the current absorbed by the lifting motor has exceeded the threshold. This can happen if

a rack or other heavy material was placed on the hood.









ALARMS THAT DON'T STOP THE DISHWASHER (SHOWN ON THE USER INTERFACE AT REGULAR INTERVALS)

b1 Drain not efficient

Has the overflow been removed?

Is the water drain blocked?

Is the drain pump blocked?

Are the air trap and tank pressure switch clean?

Is there a constriction in the drain tube?

Is the pump breather pipe returning to the tank clogged or constricted?

Does the tank pressure switch work properly?

Is there a hole in the drain tube (only for versions with drain pump)?



b2 Overflow alarm

Is the water drain blocked?

Are the air trap and tank pressure switch clean?

Does the tank pressure switch work properly?

Is the load solenoid valve blocked? (see electrical wiring diagram - YV1 Filling solenoid valve)

Is the load solenoid valve relay stuck? (see electrical wiring diagram - RL5 relay of AP2 board)



C1 Boiler temperature rise too fast

Does the boiler level sensor work properly? The boiler could be empty.

Are no-original power resistances installed?



C2 Boiler temperature too high

Has the boiler temperature been changed (btC - increased above 90°C)?

Has the software alarm value been modified (bH,)?

Does the boiler level sensor work properly?

Boiler relay/relays sticked (see electrical wiring diagram - RL1/ RL2/ RL3 relays of AP2 board)?



C3 Tank temperature too high

Is the feed water above 60°C?

Has the software alarm value been modified (tHi)?

Is the rinse water temperature too high?

Is the tank relay stuck (see electrical wiring diagram - RL4 relay of AP2 board)?



C4 Tank temperature sensor out of order

Is the temperature sensor broken or disconnected (see electrical wiring diagram - ST1 Tank

probe)?

Is the temperature sensor connector correctly inserted?



C5 Tank temperature sensor out of order

Is the temperature sensor short-circuited (see electrical wiring diagram - ST1 Tank probe)?



C6 Boiler temperature sensor out of order

Is the temperature sensor broken or disconnected (see electrical wiring diagram - ST2 Boiler

probe)?

Is the temperature sensor connector correctly inserted?



C7 Boiler temperature sensor out of order

Is the temperature sensor short-circuited (see electrical wiring diagram - ST2 boiler probe)?



C10 Rinse temperature sensor out of order (only on machines with temperature sensor on the rinse circuit)

Is the temperature sensor broken or disconnected?

Is the temperature sensor connector correctly inserted?

C11 Rinse temperature sensor out of order (only on machines with temperature sensor on the rinse circuit)

Is the temperature sensor short-circuited?

C13 Rinse pump out of order (the water level of the boiler does not decrease)

Does the rinse pump work correctly?

Is there any bottleneck in the hose, that connect the air trap and the board sensor?



WARNING:

Alarms C2, C6 and C7 lock the boiler temperature control.

Alarms C3, C4 and C5 lock the tank temperature control.

In the case of alarms C6 and C7, the boiler waiting phase is not executed (the rinse may be performed

with cold water) and, during the initial warm-up and subsequent rinses ( btF > 0 ), the boiler heating

phase is not executed.

In the case of an open probe error ( C4, C6 e C10 ), the displayed temperature is 10°C

In the case of a shorted probe error ( C5,C7 e C11 ) , the displayed temperature is 99°C.



E1 Communication error

Is the connection between main board and control panel correct? Are the connectors correctly

connected?

Are connector contacts clean?

E2 Tank temperature low

Does the tank heating element work properly?

Are the connectors correctly connected?

Are the dishwasher feed voltage and current correct?

Is the relay RL4 (see electrical wiring diagram - RL4 relay of AP2 board) on the board disconnected

or faulty?

E3 Boiler temperature low

Does/do the boiler heating element/s work properly?

Are the connectors correctly connected?

Does the possible remote control switch connected to the heating element work correctly?

Is there power at the remote control switch input terminals?

Do boiler relays (see electrical wiring diagram - RL1/ RL2/ RL3 relays of AP2 board) work properly?



CAUTION: IF THERE IS A MALFUNCTION ON RELAY RL1 AND THE BOILER HEATING ELEMENTS

ARE FED BY MEANS OF A REMOTE CONTROL SWITCH, THE BOARD DOES NOT

HAVE TO BE REPLACED; JUST MOVE THE BOILER HEATING ELEMENT CONNECTOR TO

ONE OF THE TWO FREE POSITIONS ON THE BOARD.

CAUTION: WHEN ONE BRANCH OF THE HEATING ELEMENT DOES NOT WORK AND THE

OTHER TWO CONTINUE TO FUNCTION, ON REACHING THE SET TEMPERATURE VALUE,

ALARM 3 DISAPPEARS AND REAPPEARS IN THE SUBSEQUENT RINSE PHASE. THIS

ALSO OCCURS WHEN A PHASE IS MISSING.



Dado
0helpful
2answers

Frigidaire oven displaying the f1 error code

You are experiencing a runaway temperature, or too hot of a temperature for the control board and sensors within the unit. When the unit gets this error code it shuts down for safety reasons. You would need a professional to diagnose the connections and control wiring to the control board, and the elements for safety.
0helpful
1answer

Baxi duo tec e160 code

Fault Code E160 on a Duotec Boiler is a fan fault.

Mine has just gone for the 2nd time! Gas engineer is on his way......
0helpful
1answer

I have a RENOVA boiler and on the screen it shows F1 problem. What does it mean?? And what I have to do?? Thank you

You simply do not have enough water pressure inside your heating system and therefore the Boiler will not fire up. On your Control Panel, press the Bar/Mode button to display the system pressure... Then under the Boiler you will find a valve (On ours its a Blue knob), turn it anti-clockwise to let in more water, when the indicated pressure reaches that required by your system (On ours its 1.7 Bar) shut the value (Turn knob clockwise) - Then you can restart the system.
0helpful
1answer

Showing F1 on display boiler makes a thudding noise then goes to F1 mode. Smell of gas.

Hello
Sounds like a low water cutoff switch is stoping burner from lighting.

Check that you have at least 15psi of water pressure on the boiler guage.

Try to reset the cutoff switches.
11helpful
1answer

I was drying and the dryer shut off and gave an error message of E64

Hi

Error code E64 means Heater Open Circuit. This error appears when the Heating element or wiring to the heating element is defective. To clear the error code (s): Press and hold the far left key under the display and “cancel” buttons simultaneously for 3 seconds. If the error appears again then you’ll need to check heater coils and connections for open circuits. Use a multimeter to check the heater element, use Rx100 setting on the multimeter. It should display 30-33 K ohms as the resistance. If it is less than this or exceeds this limit then the element has gone bad and you would need to replace the element. Hope this helps...
Daniel
0helpful
1answer

Valliant combi boiler Fault Code F1 What does it mean

f1 means failed to fire check you have gas to bolirt and check water leval on boiler 1.5 bar
4helpful
3answers

F1 display and beeping

F1 Power to element relay energized during time of day display.
1. Wiring harness shorted.
2. Or change power relay board (PRB).

Note: for double ovens, change second oven board.
Not finding what you are looking for?

154 views

Ask a Question

Usually answered in minutes!

Top Jenn-Air Kitchen Ranges Experts

Paul Carew

Level 3 Expert

3808 Answers

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Cindy Wells

Level 3 Expert

6688 Answers

Are you a Jenn-Air Kitchen Range Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...