SOURCE: After installation of canon IR 2520 its give me an E000716
E716
Erroneous communication with optional cassette or 2-way unit
0000
After the presence of a cassette pedestal or a 2-way unit has been detected, the communication fails to be normal for 5 sec.
1. Check the cable.
2. Replace the DC Controller PCB (PCB4).
3. Replace the Cassette Pedestal Driver PCB.
4. Replace the 2-way unit driver PCB.
0010
When the communication with the 2-way unit is faulty after detecting the connection with the finisher.
1. Install the 2-way unit.
2. Check the cable.
3. Replace the DC Controller PCB (PCB4).
4. Replace the 2-way unit driver PCB.
SOURCE: After installation of canon IR 2520 its give me an E000716
communication error between the added cassette pedistal. check all the connectors. make sure you have programmed the correct size for this unit in additional functions ,make sure of a a4 or ltr selection where ever your at in this world.