Question about Xerox Office Equipment & Supplies
right side of the page. Tried new toner cartridge, no change. There are a few different issues that it could be, the feed rollers could be dirty, as well as the belts into the fuser. Be really careful
...vacuum. 3. Misalignment of PCU band If your PCU band has moved off to the right or left of the roller, it will need to be realigned. A simple check of the right and left position on the roller will ...
...right. Anne thanks Anne, This could be several things-here is a list... 1. transfer roller or belt dirty, especially if inside of printer looks like it needs a cleaning. You could vacuum with toner ...
...right. You may need a screw driver to get them loose. Untighten them completely. They will NOT come out. They are designed to loosen, but stay attached to the transfer belt component. That is a good ...
...belt to the left by a couple of milimeters and all worked fine... absolutely agree move the huge rubber band which runs right through the photoconductor unit sideways (roll over rollers while pushing ...
...right. Just wipe it until it's clear on the inside. The sensor can now see through the window and you should be okay. 2. On the machine there is a sensor that looks trough the waste tank. Even though ...
Question about Epson Office Equipment & Supplies
...right door and you will see a Green Wheel about half way down on the back side. Turn this wheel so the cam inside turns untill it is about 100 - 110 degrees further round (anti clockwise) than it is ...
439 questions posted
Usually answered in minutes!
1,135 Questions
1,012 Questions
743 Questions
623 Questions
406 Questions