Rinnai Heating & Cooling - Page 3 - Recent Questions, Troubleshooting & Support

0helpful
3answers

We have a rinnai convector

There are a couple of things that can cause this odor. But, being sure it's really a gassy odor is more important. It must smell like "rotten eggs" to be gas. If that is the odor you're smell, turn the heater of and contact an authorized Rinnai dealer for service.

If however the odor does not meet the "rotten egg smell", there are other things that cause the odor, but it's not really from the heater.

If you have painted or stained within the last 2 weeks, the heater has picked up the odor of the fumes (which you probably didn't notice) and has made time 50 times worse. The same holds true for carpet cleaning or new carpeting odors. If this fits the scenario, discontinue using the heater for a week or two until the odors subside. In the meantime, if weather allows, air the house out. Also, remove and clean the heaters filter, before restarting the heater,

I hope this helped you to troubleshoot & solve the problem.
8/6/2021 4:24:56 AM • Rinnai Heating &... • Answered on Aug 06, 2021
0helpful
1answer

My Rinnai gas stove yellow flame, how we can fix it ?

Yellow flame means O2 starvation causing CO emmisions that are deadly! Have it serviced by a qualified gas engineer.
6/25/2021 7:07:17 AM • Rinnai Heating &... • Answered on Jun 25, 2021
0helpful
1answer

The starter ignition on my Rinnai Galaxie 21 wont start. Have tried vacumming any dust from the gas panels and ignition no luck.

Chung toi la cong ty co phan cong nghe KozyHome chuyen cung cap cac san pham noi that chat luong, uy tin. KozyHome Locaition: 21Bis Hau Giang, Phuong 4, Quan Tan Binh, Thanh Pho Ho Chi Minh 700000 Email: [email protected] Phone: 0906 353 247 Website: https://kozyhome.vn/danh-muc/sofa/sofa-vai-ni/ Facebook: https://www.facebook.com/kozyhome.vn/ Twitter: https://twitter.com/sofakozy
6/14/2021 6:39:35 AM • Rinnai Heating &... • Answered on Jun 14, 2021
0helpful
1answer

My rinnai wall furnace, 556, just runs and runs. Past set point and keeps going. Will not shut off.

Faulty thermostat. It needs replacing.
6/10/2021 6:08:59 PM • Rinnai Heating &... • Answered on Jun 10, 2021
0helpful
1answer
0helpful
1answer
0helpful
2answers

Rinnai model REH-25T-N pilot comes on but will go right back out when you let off button.

Usually happens for two reasons. The thermocouple needs replacing. This is the rod thing that glows red and is the safety for the main gas valve. The cover to the pilot flame has moved or worn away. Often you have to hold the button in for a lot longer than you think. You can also use a gas torch to heat the thermocouple if you can get access to it.
12/28/2020 12:19:19 AM • Rinnai Heating &... • Answered on Dec 28, 2020
0helpful
1answer

What is the current equivalent of the Rinnai 404

The link below is for a great natural gas option, but also has a LP gas alternative. I would recommend this option.
11/27/2020 12:53:48 AM • Rinnai Heating &... • Answered on Nov 27, 2020
0helpful
1answer

Lazer 56

Hi EJAKFbanks,

I believe by your description and my 8 years experience with Toyo Stove repair that you are missing part of the firing sequence. The firing sequence for a Toyo Stove L 56 is to blink on the burner light for 7-9 minutes, then it clicks up to the medium light (amber-yellow color). The medium light blinks and that is when the fuel pump kicks on and starts to pump. If the stove ignites, the medium light will glow for a second and then drop down to the low light (green) The low light will burn for awhile and at this time you will see a blue flame in the newer heat chamber models or a red glow, and perhaps some blue flame in the older heat chamber models, then the stove will kick up to the medium light for a bit, and then to the high light. An EE6 error code will show only when the flame is extinguished after actually taking place and a burn did occur in the chamber on low. An EE6 is usually one of 2 things: 1. There is an inadequate fuel supply for the stove to maintain a low cycle burn, or the medium, or high. Each cycle consumes more fuel than the prior one. Inadequate fuel supply can be due to a restriction in the fuel line such as icing like cholesterol in a persons arteries, or a plugged sump screen, blocked fuel line or filter, too low a quantity of fuel in the tank, or a fuel line that is not all gravity feed, as in, the fuel line runs down, down, and then up a few feet to get to the Toyo. In that case, the fuel has to rely on head pressure to get to the stove. Head pressure is the atmospheric pressure pushing on the fuel in the tank to force it up against the earth's gravity forces. Solution: You can find any restriction in the line, replace the filters, clean the sump screen, put heat on the fuel line to thaw any icing blocks. 2. An EE6 can be caused by a carbon chain developing from the burner ring, flame sensor or chamber wall to any metal part in the burn chamber. A carbon chain essentially "shorts" out the ground for the unit and the Toyo will shut off on EE6. Solutions:You can bang the side of the Toyo (Old frustrated Alaskan solution) which really just jars the carbon chain loose, clean the flame sensor, clean the fuel nozzle with a straight 3 inch wire, and stick a screw driver in the igniter (red wires) hole and rattle it around real good (another old Alaskan trick). Often, those three things will get your stove running again if it is a carbon chain. The problem will likely occur again, but it will buy you some time until you can get a tune-up done. Most likely, you need a tune-up. Question: When was your last tune-up? Toyo's should be tuned up every 2 years. Tthe book says every one year, but in my experience, every two years is the best bang for the customers buck. The three year mark usually begins showing signs of metal fatigue in other parts of the burn chamber/heat exchanger system so the costs rise a little each year, unless you are a lucky Toyo owner and for some odd reason, your stove can go 3 years between cleanings without any ill effect. If you get your stove running, run it hard on High for about 2 hours to clean and burn all the carbon out. Good Luck! toyotech, North Pole, Alaska
10/20/2020 9:01:43 AM • Rinnai Toyostove... • Answered on Oct 20, 2020
0helpful
1answer

Rinnai spectrum 28 can't remove filter

I can't believe no one answered this question properly. When the heater is transported new the fan filter sits below its normal level at the front so it will not slide out. The installer is meant to reposition it when instructing the owner how to operate the heater. you need to loosen the 2 screws holding the bottom panel. Then pull the bottom panel out a bit at the bottom and then lift the front of the filter up into its proper position so it can easily be removed and cleaned. Re tighten the screws in the bottom panel and your done.
9/12/2020 2:05:00 AM • Rinnai Heating &... • Answered on Sep 12, 2020
0helpful
3answers

Monitor 422 lights then goes out

Sounds like your flame rod may be dirty. You can take it out and clean it with some steel wool or sandpaper or emory cloth. If this doesn't help email me at [email protected].
12/7/2019 10:18:52 PM • Rinnai Toyostove... • Answered on Dec 07, 2019
0helpful
1answer

My rinnai displays p6! What does this mean and its not blowing heat?

Have the same thing is there a fix for this
7/24/2019 11:51:11 PM • Rinnai Heating &... • Answered on Jul 24, 2019
0helpful
1answer

Rinnai Galaxie 21 Third Burner Button stuck

When turning the 2nd burner on keep the button depressed.

Press the 3rd burner button down untill it stops.

Hold both in that position!

As you slowly release the 2nd burner button, continue pressure on 3rd button while gently wrigling it back and forth/side to side .

As the 2nd burner button is coming up and you fidget the 3rd they will hit a happy medium. This happens around about the middle of slowly releasing burner 2s button.

Dont use excessive force, also if its just been started up you will have to gove the machine 5 mins to warm up before this works.

Can easily upload youtube video if so wish
7/20/2019 11:52:20 AM • Rinnai Heating &... • Answered on Jul 20, 2019
0helpful
1answer

Rinnai infinity 26 heater with error code 82 after power surge

Cycle the power and see what happens.
7/11/2019 12:36:02 AM • Rinnai Heating &... • Answered on Jul 11, 2019
0helpful
1answer

Have a rinnai Convector 406TR Keeps coming up with the number 62 Can anyone help?

I can't find the manual for a 406TR but sometimes the codes are preserved across similar models. The 506TR manual says the code 62 is appliance overheating / faulty fan motor. https://rinnai.co.nz/Download/ProductFile?encid=wlRVPivhogtawwUVs9imTaEmB0CjAIKlOKNwOUvXmCU~
6/28/2019 10:26:58 AM • Rinnai Heating &... • Answered on Jun 28, 2019
Not finding what you are looking for?
Rinnai Logo

1,576 questions posted

Ask a Question

Usually answered in minutes!

Top Rinnai Heating & Cooling Experts

Paul Carew

Level 3 Expert

3808 Answers

Cindy Wells

Level 3 Expert

6688 Answers

Brad Brown

Level 3 Expert

19187 Answers

Are you a Rinnai Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides