1 Answer

...generator. This will energize the field windings and should cause the armature to produce dc voltage at the brushes and produce a nice magnet. If there is a short in the field or broken wire or ...

Ad

Question about Powermate Premium Plus 6250W Portable Generator

1 Answer

generator. This will energize the field windings and cause the armature to produce dc voltage at the brushes and produce a nice magnet if all is well. If dc voltage is present at comutater, remove 12v

Ad

Question about Sport 1850 Generator

1 Answer

...DC output. Remove the rectangular snap-fit cover from end bell Start generator making sure it's at rated RPM Using volt meter test brush terminals. Use red+ lead on top or right brush black is - ...

Question about Sport 1850 Generator

1 Answer

...lack of DC output COULD possibly prevent the stopping. There are likely fuse(s) between the low voltage winding and a rectifier to generate the DC. SOMETIMES these are even inside the generator

Question about Sport 1850 Generator

3 Answers

...small gas engine spins a DC generator, which in turn feeds 12 volts to the inverter which changes or inverts the DC voltage to AC. Seems even a simple explanation gets complicated, hope this

Question about Sportsman GEN7000LP Portable Propane Generator W/Electric Start

1 Answer

...DC voltage then the capacitor in the end of the generator housing is bad, or the AVR. If you do have voltage then make sure the slip rings are clean and shiny, from there you may have a rotor or ...

Question about Sportsman GEN7000LP Portable Propane Generator W/Electric Start

1 Answer

...generator is working. Another test is carried out with the use of a voltage tester (multi meter). Set on dc volts test the batteries voltage eg 12vdc, start the bike and re test the voltage should be ...

...meter schould read 25 to 30 volts DC if none of these readings are achived generator repair is necessary. if readings are aceptable and battery still is not getting charged replace regulator good ...

Question about Sportsman GEN7000LP Portable Propane Generator W/Electric Start

2 Answers

...generator core remanence disappears or is too weak 2 excitation circuit wiring error 3 excitation circuit is unreachable 4 The circuit interruption on the DC side of the rotary rectifier is ...

Question about Sportsman GEN7000LP Portable Propane Generator W/Electric Start

2 Answers

...DC only. It is probably an AC generator coupled to inverter technology that gives it the capability of offering those different welding options. That means there is some quite fancy electronic ...

Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top Electrical Supplies Experts

Brad Brown

Level 3 Expert

19187 Answers

john h

Level 3 Expert

29494 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66975 Answers

Are you an Electrical Supplies Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...