How to remove air inlet cp 741
It appears that the inlet bushing (item 42) on this model is threaded to the motor housing. Take the tool to a vise, install upside down, make sure that the hammer case is installed so that you have a hard surface to clamp on (watch the motor housing it is plastic), find a box end wrench and turn the bushing counter clock wise (left).
8/29/2014 1:01:52 AM •
Chicago...
•
Answered
on Aug 29, 2014
•
161 views
How to remove air inlet in cp 741
It appears that the inlet bushing is threaded to the motor housing.
If possible place the tool upside down in a vice, place the wrench on the inlet bushing and turn counterclockwise to loosen.
Follow this like for a parts list:
Part Listing Order Page
1/3/2015 8:51:23 AM •
Chicago...
•
Answered
on Jan 03, 2015
•
684 views
Turns slow and no torque
Take some contact cleaner and spray it in the air intake couplin and then plug it into you air line and pull the trigger.be careful not to get sprayed in the face.do this a couple of times them do the same thing with tool oil . if it is dirty most of the time this will solve the trouble.
9/14/2016 2:26:26 AM •
Chicago...
•
Answered
on Sep 14, 2016
•
515 views
How do I remove pneumatic staples from furniture.
try a large pair of pliers.
straighten the staples as much as you can, grip one leg with the pliers about 1/8" from the wood, and tap the pliers with a mallet or wood block.
alternate "till you can grip the crown.
1/22/2015 10:54:57 AM •
Chicago...
•
Answered
on Jan 22, 2015
•
131 views
Working temprature of compressure is increasing in short time and comoressure get stopped.
It is normal for the air to heat up as pressure increases. The temp can easily increase to 200 degrees depending on pressure. Most likely problem causing your motor to stop is the capacitor (should test to within 10 percent of rating) or using too long /thin extension cord. If capacitor is good and low power is not problem, then make sure that the check valve (non-return valve) is not leaking pressure back to the pump causing motor to overload. Good luck
3/24/2014 8:48:53 PM •
Chicago...
•
Answered
on Mar 24, 2014
•
92 views