20 Most Recent Meiko DV 80.2 Dishwasher Questions & Answers

0helpful
2answers

MEIKO DV 80.2 ERROR CODE 305

305 Booster content is insufficient for rinsing See error code 301, booster tank level sensor defective/disconnected, water inlet strainer is soiled, booster tank vent is clogged, anti siphen flap. 301 Level 1 not reached when filling (number of cycles exceeded) Booster pump output low/defective, rinse nozzles clogged, wash tank level sensor soiled, moisture in sensor tube, hose kinked or not water tight.
1/14/2024 1:52:40 PM • Meiko DV 80.2... • Answered on Jan 14, 2024
0helpful
1answer

DV 80T

are all 3 cycle lights flashing together? if so then the eeprom has blown (the little pcb fitted at 90deg to the main spuel 6 card. This component is very prone to failing where there are power cuts or surges . You will only need to replace the eeprom and not the main card but make sure power is ok before you fit new one or it may blow again.
Regards Kit
12/2/2022 7:37:33 PM • Meiko DV 80.2... • Answered on Dec 02, 2022
0helpful
1answer

Error code 307

307 Wash tank level sensor defective (short circuit) Check connection, defective sensor, I/O board defective. Per service manual.
10/7/2017 2:10:54 AM • Meiko DV 80.2... • Answered on Oct 07, 2017
0helpful
1answer

Unit locked in service mode

Press the "0" key at any time to exit programming mode. Per Service Manual.
10/7/2017 2:08:17 AM • Meiko DV 80.2... • Answered on Oct 07, 2017
0helpful
1answer

Error codes 206

206 Increase in wash time Booster not ready for rinsing at right time. See error code 205. 205 Temperature increase not reached Booster heater not working, heat elements are open, defective temp sensor. Per the service manual
10/7/2017 2:05:57 AM • Meiko DV 80.2... • Answered on Oct 07, 2017
0helpful
1answer

Error 121

121 Door/hood is open, door switch malfunction Close door and restart wash cycle, check switch. Per the service manual.
10/7/2017 2:04:01 AM • Meiko DV 80.2... • Answered on Oct 07, 2017
0helpful
1answer

Meiko error 203

203 No change detected by level switch during rinse pump operation Level switch defective/disconnected, booster pump defective/disconnected, start cap defective/disconnected, no signal from I/O board, check microswitch manually. This is per their service manual.
10/7/2017 1:59:43 AM • Meiko DV 80.2... • Answered on Oct 07, 2017
0answers
0answers
0answers
0answers

Error 702

Be the first to answer 5/7/2014 6:30:32 AM • Meiko DV 80.2... • Posted on May 07, 2014Be the first to answer
0answers
0answers

Info 121

Be the first to answer 11/24/2013 3:16:24 AM • Meiko DV 80.2... • Posted on Nov 24, 2013Be the first to answer
0helpful
1answer

I run dv 80.2 without wash arm, when i put back

possible door seal.
10/2/2013 10:08:56 PM • Meiko DV 80.2... • Answered on Oct 02, 2013
Not finding what you are looking for?
Dishwashers Logo

82 questions posted

Ask a Question

Usually answered in minutes!

Top Meiko Dishwashers Experts

john h

Level 3 Expert

29494 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66980 Answers

Robbie Goodwin

Level 2 Expert

384 Answers

Are you a Meiko Dishwasher Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Meiko Dishwashers

  • Meiko Dishwashers

Most Popular Question

mekio dishwasher wont turn dv 80 2

  • Dishwashers
Loading...