Questions & Answers for: klimaire p5

Question about Klimaire KSWG009H113 Split System Air Conditioner

1 Answer

doesn't work get the code HS ? klimaire 12000 btu heat pump. The machine gives me a code HS or H5? check your filters and coils for blockages , both these codes are pressure related , if the filter is

Ad

Question about Klimaire KSWG009H113 Split System Air Conditioner

2 Answers

Klimaire KSWG009H113 Split System Air...? system Klimaire KSWG009H113 Split System Air...? system doed not seem to be heating properly - luke warm air check your filter if its really dirty it will ...

Ad

Question about Klimaire KSWG009H113 Split System Air Conditioner

1 Answer

After installing my klimaire mini split unit yesterday I heard the freon go through the unit and it worked great.Today when I turned the unit on the fan would work but the unit would not cool it also ...

Question about Klimaire KSWG009H113 Split System Air Conditioner

1 Answer

I just installed a Klimaire KSWG009-C113. It cycles on and off approx. every 3 minutes. Line set vertical drop is 20 ft, total is 25 ft suction pressure is 115 to 125 psi indoor temp is 32 degrees C ...

Question about Klimaire KSWG009H113 Split System Air Conditioner

1 Answer

...p5 error code on the indoor unit of my klimaire minisplit I have a 3 unit split. I found out that you can not have one unit set to warm and the other to cold. The compressor doesn't understand it. ...

Question about Klimaire KSWG012H113 Split System Air Conditioner

1 Answer

klimaire mini split error code E1 turns on for 30 second then shuts down and says error code E1 hi, E1: communication error between indoor and outdoor unit. Air Conditioning Fault Codes

Question about 18,000 BTU KSIM DUCTLESS MINI SPLIT INVERTER AIR CONDITIONING HEAT PUMP"

1 Answer

I have a Klimaire 16 Seer Dual Zone Mini Split Heat Pump AC and the outside unit fan/fan motor have stopped working where can I replace this at? I live near Dallas Tx surely there is something nearby?

...Celsius, cyccle breaker off and back on, change the batteries on the remote controller. ...

I have a klimaire mini split.when it was installed there was a screw in the electrical panel box that penetrated the feed wire and caused the breaker to trip however after repairing the wire the conde

Question about Klimaire KSWG012H113 Split System Air Conditioner

1 Answer

Klimaire KSWG012H113 Split System Air Conditioner After about 30 minutes of AC running unit shuts off. Run light blinks 4x. Can turn unit back on and it will run another 30 minutes or so then shut off

Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top Heating & Cooling Experts

Paul Carew

Level 3 Expert

3808 Answers

john h

Level 3 Expert

29494 Answers

Brad Brown

Level 3 Expert

19187 Answers

Are you a Heating & Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...