Questions & Answers for: ignition fault boiler

Question about Centre DX - Mango

1 Answer

...fault happens and I've looked through the manual to try and get some idea. Do you think it could be the pump getting stuck or do you have any other ideas? Thank you for your help. im an engineer and ...

Ad

Question about Valiant 6380iPTD-01 Notebook

6 Answers

...Ignition fault, you either have no gas or there is a problem with the electrode or gas valve probably don't try messing with gas appliances, you need to get a registered gas engineer to come and have ...

Ad

Question about Valiant 6380iPTD-01 Notebook

1 Answer

...boiler will ignite and then immediately go into a lockout condition (fast flash on the fault indicator). In the previous few day the central heating would run for approx. 10 minutes before going into ...

Question about Valiant 6380iPTD-01 Notebook

2 Answers

...fault in gas supply, gas pressure too low. Boiler will ignite but goes out within minutes? HELP! Thank you Regmeister for your advice about checking the Gas lever,, mine is not clear when it is on or ...

Question about (01946) External Floppy Drive

1 Answer

...ignition still firing when on main burn is it poss that air pressure switch fault or FDP fault ? or PC.          hariston sx 20 boiler It sounds to me as if the Triney Valve ...

Question about (01946) External Floppy Drive

1 Answer

...fault, but appears to be no ignition clicking, and therefore no flame. Gas supply is good. Hi, if the ignition module fires or tries to fire 4 times, this indicates the module is faulty and locks out ...

Question about (01946) External Floppy Drive

2 Answers

...FAULT CODE L2 ALMOST EVERY DAY SINCE INSTALATION DEC 2010 is boiler still under warranty? normal warranty lasts at least 2 years if so get ideal to send one of their engineers out L2 relates to flame ...

Question about (01946) External Floppy Drive

1 Answer

...ignition fault (lockout) failed to light.cause:no gasinsufficient gasincorrect gas valve adjustmentelectrode ignition lead defectiveelectric igniter defectivecheck air inlet ductcheck connections to ...

Question about (01946) External Floppy Drive

1 Answer

...IGNITION fault. What can be done Not a problem. I have noted that the F4 Ignition fault you are getting is with a Glowworm 18si boiler. This relates to the burner system and will need a gas licensed ...

...ignition..pcb Start by diconnecting main supply to Boiler (at the boiler input) and see if it trips the electric. This would point to fault in wiring from board to boiler. Then check several points ...

Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top Baby Gear Experts

Jennifer Rock
Jennifer Rock

Level 2 Expert

153 Answers

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

john h

Level 3 Expert

29494 Answers

Are you a Baby Gear Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...