Master
2,133 Answers
- Posted on Feb 11, 2011
Re: What does error code po5 on a sanyo cassette air con...
P05-Current value sent from MDC on outdoor unit control PCB is low. No AC power input for 3
minutes or longer: pre-trip - 5
Solution:
1. Check R/S/T power.
2. Check inverter control PCB.
3. Check outdoor unit control
PCB.
Thanks.
×