I have a split unit
the thermostat switching off the unit as it has reached the set temperature
could also be a timer setting activated
read the user manual carefully
Air conditional water drip
That happened to us. It was a broken pump, pump was up in attic. attached to our inside air-con unit. We had it fitted on an inside wall of the house, and so a pump must be installed to take away the condensed water to the outside of the house. Hindsight being 20/20 I would never buy one that needed a pump to get the condensed water out of the house. We would have put it an outside wall where the water goes straight outside, no pump needed. Our First pump lasted just over 2 years so warranty was expired. Cost us over NZ$500 to have new pump installed. Never again. Only attach your unit to an outside wall, even it looks prettier on the wall where it would need a pump. Bottom line:- Don't touch a pump. Pump was cheap but labor cost for serviceman astronomical! Bet of luck.
WHAT IS PSI SUCTION PRESSURE IN SPLIT AC WHEN UNIT IS IN OFF CONDITION
there is no suction at all when the machine is off as the gas equalizes around the system
all you will read is the pressure of the gas in the system and that will tell you nothing
to read gas pressures you need to know the type of gas in the system , have gauges that can handle the high pressures and have two on a manifold so that you can read suction and high side pressure differences
That way you can see if the system is low on gas or over charged
SANYO SPLIT TYPE AIR CONDITIONER LEAKING
The leakage is probably from condensation and there should be some sort of drain for it. You should check to see if it is clogged or partially clogged. Also since you say it does it when it hasn't operated for a while you may want to check out where the lines pass through the wall and make sure that it is sealed up there so you don't get leakage from out side.
What is the capacity of this model no. sap-306
the capacity of the system is on the plate /decal located on the inside section on the end or on the outside section near where the pipes are fitted.
It will be either a btu rating or a kw rating