Tip & How-To about Office Equipment & Supplies

ERROR codes Canon 3050

Canon 3050 E000 Fuser temp low. Heat lamp, thermoswitch, thermistor, SSR E001 Fuser temperature too high or shorted thermistor E002 Fuser temperature too low E003 Fuser temperature too low E004 SSR, or lamp reg. board E010 Drive problem E022 DV unit switching problem E030 Counter not working/open E202 Scan problem. Scan sensor, scan motor E204 Scan problem. Scan sensor, scan motor E210 Lens problem. Lens sensor, lens motor E220 Exposure lamp E240 DC controller (main board) E400 RDF circuit board E401 RDF pickup motor drive E402 RDF belt motor drive E403 RDF feed drive problem E404 RDF exit motor E411 RDF sensor problem E500 Sorter board problem E510 Sorter feed motor E512 Sorter delivery motor E514 Sorter delivery motor E520 Sort stack motor E530 ******** motor E531 Stapler motor E535 ******** motor E540 Shift problem E541 Shift problem E710 DC controller E711 DC controller E712 DC controller. Document feeder board or cable

Posted by on

Office Equipment & Supplies Logo

Related Topics:

Related Questions:

0helpful
2answers

Error Code E000001-0004

The main thermistor TH1 has poor contact or open circuit.The thermal switch TP1 has an open circuit.The fixing heater has an open circuit.The SSR is faulty or the DC controller PCB.After the main power switch is turned ON the temperature detected by the main thermistor does not reach 70 C.The error must be reset in service mode :COPIER - FUNCTION - CLEAR - ERR
0helpful
2answers

the canon ir2016 j displays E003 nd i know its fixing but i can't fix it what shall i do?

ferst solved[ astrix 2 8 astrix} servise mode athore ways replase fuser elament. E000 Fuser temp low. Heat lamp, thermoswitch, thermistor, SSR E001 Fuser temperature too high or shorted thermistor E002 Fuser temperature too low E003 Fuser temperature too low E004 SSR, or lamp reg. board E010 Drive problem E022 DV unit switching problem E030 Counter not working/open E202 Scan problem. Scan sensor, scan motor E204 Scan problem. Scan sensor, scan motor
0helpful
1answer

canon copier error message "error001"

"E000" Low fuser temp. (Heat lamp, thermoswitch, thermistor, SSR) "E001" High fuser temp. (Thermistor) "E002" Fuser temp. too low "E003" Fuser temp. too low "E004" SSR, Fuser temp too highchange thermistor in fuser
Not finding what you are looking for?

655 views

Ask a Question

Usually answered in minutes!

Top Office Equipment & Supplies Experts

k24674

Level 3 Expert

8093 Answers

Brad Brown

Level 3 Expert

19187 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66980 Answers

Are you an Office Equipment and Supply Expert? Answer questions, earn points and help others

Answer questions

Loading...