Questions & Answers for: disconnect split system air conditioner

Question about LSC091PMA Split System Air Conditioner

1 Answer

...split system air conditioner. the inside fan turns on fine but the out door will not. i pushed the contactor in (located at the outdoor fan)that seems to turn on the fan. i measured the voltage with ...

Ad

Question about Art Cool LA091HNP Split System Air Conditioner

1 Answer

Water leaking out from wall mounted head unit. A little too vague, but probably the evaporator drain is disconnected, plugged up or was never installed.

Ad

Question about AmcorAire UCHW-H12AF2 Split System Air Conditioner

1 Answer

e7 error message The E-7 error code means the 2 wire defrost cable between the outdoor & indoor unit is disconnected or broken

Question about Art Cool LA181CNW Split System Air Conditioner

1 Answer

...muilty system midwall unit error code c1 C1-Indoor unit return air sensor fault, Open or Short. Disconnect sensor from PCB and measure resistance. 8 kOhm at 30C and 13 kOhm at 20C if not replace ...

Question about Art Cool LA121HNP Split System Air Conditioner

1 Answer

...air conditioner 24awn error code message Ch 6 inside fan runs outside unit not working CH-06 REFERS Indoor unit coil sensor fault. Disconnect from PCB measure resistance. 10 kOhm at 10C and 4 kOhm at ...

Question about Art Cool LA181CNW Split System Air Conditioner

1 Answer

...split system ch 46 error? help!!! Ch-46Outdoor unit suction sensor fault. Disconnect from PCB and measure resistance. 10 kOhm at 10°C and 4 kOhm at 30°C. If OK replace PCB, if not replace ...

Question about LS122CE Split System Air Conditioner

1 Answer

split system, LSK182V. Since installation it has periodically stopped with a light flashing 6 times in a cycle. The local repairer doesn't know what it means!!! I have to power cycle the A/C to get it

Question about AmcorAire UCHW-H12AF2 Split System Air Conditioner

1 Answer

...Split System Air Conditioner units -- 2 years old. One works fine, but the other does not blow heated air (Heat Mode). It is cold outside, but the good unit is blowing heated air at the same time the ...

Question about AmcorAire UCHW-H12AF2 Split System Air Conditioner

1 Answer

...eBayGoodman 3 Ton 14 SEER Heat Pump Split System GSZ140361 with Installation Kit.10k Heat Strip,Thermostat,Wiring, Disconnect Box,Pad. $1,912.00; Buy It

Question about LSC121PMA Split System Air Conditioner

1 Answer

How do I locate the correct resistor for error ch46 Outdoor unit suction sensor fault. Disconnect from PCB and measure resistance. 10 kOhm at 10°C and 4 kOhm at 30°C. If OK replace PCB, if not replace

Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top Heating & Cooling Experts

Paul Carew

Level 3 Expert

3808 Answers

john h

Level 3 Expert

29494 Answers

Brad Brown

Level 3 Expert

19187 Answers

Are you a Heating & Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...