Hello, Most likely your Glowplug Relay is bad, and it supplies power to the Glowplug Timer which also may be bad.
Just follow the wires that are on the Glowplugs up to the Glowplug timer. Use a Voltmeter and check if the power wire that goes into this Timer has fire when the Ignition is turned to the RUN position. If there is fire going into the Timer from the power Relay, pull off one of the Glowplug wires and ground 1 end of a testlight and put the other end on the Glowplug wire.
The Timer itself will kill the power after a predetermined time based on Temperature. The colder the engine, the longer the Glowplugs stay lit. If you have power reaching the Glowplug, your power Relay is fine. You just have to observe how quick the Timer stays on.
The Glowplugs only have 1 or 2 chances to do their job at the Start-up. They are needed to make a Diesel start cold. Cold meaning at outside AIR temperature, and engine block temperature. There should be clicks under the hood and the lights should flicker in rhythm to the clicks if the Timer is working.
If you find that both the Timer and Power Relay are working, the Glowplugs need to be tested. They come out like sparkplugs. But you test them either on a special machine or use battery jumper cables. To test, hook one battery cable to the Glowplug base, avoiding the thread. Then take the other cable and arc it on the top of the Glowplug.
Caution, you can melt the Glowplug. If you get a bright glow, the Glowplug is good. If the Glowplug is dark or very slow to glow, it is bad. This should be all you need. Would appreciate a note after you fix it.