Questions & Answers for: mit1020 megger battery

Question about MIT1020/2 Megohmmeter, Battery

1 Answer

BR.D Code Loosing Power and this is the Code on the screen BR>D get it serviced at Megger

Ad

Question about MIT1020/2 Megohmmeter, Battery

1 Answer

i've an insulation machine megger S1-554/2 i've do test and there's error message appears "Br.d" what's does it means??? error 78 what it means?\

Ad

Question about MIT1020/2 Megohmmeter, Battery

1 Answer

br.d code for megger Nothing you can do, send back to Megger to get repaired.

Question about MIT1020-2 10kV Insulation Tester

1 Answer

power can not be switched on after battery disconnected it's battery operated unit (I think) connect battery back

Question about MIT1020-2 10kV Insulation Tester

1 Answer

why power can not switched on after battery replaced if your unit worked before battery change - check battery connections and also if there is any fuse there - make sure that everything is connected ...

Question about MIT1020/2 Megohmmeter, Battery

1 Answer

br.d code on MIT515 Megger Send back to Megger for repair.

Question about MIT1020/2 Megohmmeter, Battery

1 Answer

what does E 78 mean in mit1020/2 test mode Unit produced E78 on start-up. Transformer lead broken / not connected Connect lead or replace transformer Incompatible measurement board software Change ...

Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top Measuring Tools & Sensors Experts

Brad Brown

Level 3 Expert

19187 Answers

ADMIN Eric
ADMIN Eric

Level 3 Expert

39391 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66975 Answers

Are you a Measuring Tools & Sensors Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...