...Problem is usually a dirty charge corona wire. There is a cleaner on the drum unit, slide this across and back 2 or 3 times. If not, then the corona wire itself is missing or broken, change
...to bottom. I already went through the troubleshooting in the manual and the drum unit corona wire. open the front cover and try to see if there is any piece of foreign object blocking the imaging ...
...corona wire 4. replaced drum sounds like you are using generic drum and toner. try OEM (brother brand). you say copies are coming out completely gray. try printing an internal report from the control ...
Intellifax 2820 shadow or ghost printing. I cleaned the corona wire by slide the tab over 10 times yet the text is shadowed on the paper. Have you replaced the fusing unit, the hot unit in the machine
"open front cover to remove the drum. Clean the corona wire located on the drum." The fax machine instruction must be done to erase the message. The corona wire located on the drum needs to be cleaned
...corona wire of the drum ( dust on the drum). Where it is and how to clean it up.Thanks,Samir There is a blue colored slider on the drum unit, move it side-to-side 10 times. I fixed this by puting the ...
Question about IntelliFax-2820 Laser Fax
...corona wire look like and were can I find it It's thinner than human hair wire stretched acoss the paper path about the width of a page and they are clustered around the dum unit. One has a little ...
Question about IntelliFax-2820 Laser Fax
corona wire I have tried to clean the fax using canned air - but I still get a message "dust on the drum - clean corona wire" what can I do? You should find a BLUE SLIDER on top of the Drum Unit, work
corona wire and that didnt seem to help. the corona wire, which is on the drum unit only comes into play when you are receiving faxes. if i read right and its only on sent faxes, you need to clean the
Question about MFC-9120CN Multifunction LED Multifunction Laser
...corona wire cleaning tab (blue tab on the drum assembly) back to "home" position, it will block that portion of the corona wire and result in a black strip on any output where the cleaning tab is ...