I have the same compressor with the same problem. I have temporarily eliminated the thermal reset with a piece of 12 gauge hard wire and it runs just fine. However it's not adviseable to run without the thermal reset for an extended time. I tested the draw at 15.5 amps and the reset was a 17 amp. I am told by someone with superior electrical background, that I need to install a 20 amp thermal reset in it's place. I have found that mine runs best when plugged directly into a 20 amp circuit with no extention cord. But, when using an extention cord, I have a 10 guage cord that will carry the load needed to run the EC12. I also have changed to 100% synthetic oil.