SOURCE: I have an Amtrol WH7L and the control panel is
In a while the control unit will fail
On the Amtrol units the control is their weakness.Once it starts to buss it will last somewhere between a couple of weeks and a year, but it WILL eventually fail.
And while Amtrol advertise a "Limited lifetime warranty" the "Limited " part includes not putting any warranty on that control unit.
SOURCE: no hot water have amtrol boilermate
There is a device on the boilermate called an aquastat which controls the flow of hot water into it. Replace that and you should be up and running again. Joe.
SOURCE: ER3 no hot water
Er3 means that the water is being heated for more than 1 hour without reaching the set temperature.
Need new aquastat.
SOURCE: if the amtrol boilermate water
If the area it is in is heated it will not freeze any more then the water piping would.
SOURCE: Amtrol Boilermate makes whining noise
I had also this problem before, same with buzzing sounds on my Amtrol Boilermate and all I had to do was to call the local dealer and they have got it fixed.