Error message: No Reference Position Impulse (653) Sensor seems to be working because it is lighting up when close to metal tab.
SOURCE: Error Code 0320
The wiring that feeds a signal from the crank position sensor to the computer should be checked first. Disconnecting and reconnecting the wiring connector may help. Without the right diagnostic equipment, it is difficult to determine if the sensor is at fault.
SOURCE: Sharp Carousel micro/convection, sparking and says "sensor error"
Hi! try checking the capacitor.
SOURCE: hello we have a polar guillotine
Hi.
Its caused by the clutch disc binding on the shaft. Usually a strip down and clean up sorts the fault.
07808 901184
Andre Bates
Independent Polar guillotine engineeer
SOURCE: safety bolt locked on polar guillotine
I can fix that.
07808 901184
Andre Bates
Polar guillotine engineer