Question about Whirlpool Microwave Ovens
...filament terminals. Normal magnetron should be less than 1 ohm. Measure the resistance between the filament terminal to chassis. Normal magnetron should be infinite. HV CAPACITOR Remove lead wire ...
Magnetron filament. The resistance should be infinite from the filament connections to the case and a fraction of an ohm between the filament terminals with the wiring disconnected from the magnetron.
...magnetron filament resistance should be less than one ohm. If this test fails read my next post on replacement Test 2 1. With the meter set to the highest resistance scale, check from the magnetron ...
...magnetron filament resistance should be less than one ohm. Test 2 1. With the meter set to the highest resistance scale, check from the magnetron terminals to the metal magnetron housing. (Be careful ...
...filament taps, resistance 0.47 Ohms across the magnetron terminals and 205Kohms from each terminal to ground. HV transformer primary winding 0.7 ohms, secondary winding 93 ohms, filament winding 0.7 ...
...filament voltage and high voltage are both present at the magnetron terminals, and not loaded down, but there is no heat, then it's the magnetron. As a pro with over 20 years of expereince, I have ...
...Magnetron filament connectors have loosened and, due to resistive heat, the terminal connections have deteriorated and burned off. 6. Repair defective terminals as follows:Either (1) Cut away burned ...
pin to pin should read just a couple of ohms (this is the filament). A new magnetron, removed from a freight damaged microwave can be had on e-bay (and elsewhere) for around $40. I hope this helps you
...magnetron filament resistance should be less than one ohm. If this test fails read my next post on replacement Test 2 1. With the meter set to the highest resistance scale, check from the magnetron ...