Question about Desa Vent-Free Infrared Gas Heater: Vent-Free Infrared Gas Heater(18,000 BTU)

1 Answer

desa ventfree gas heater We have a desa gas vent free heater, the pilot will light but will not ignite the bunner. How do you get it to work.. Can we go around the remote? needs a new thermocouple :)

Ad

Question about Desa Vent-Free Infrared Gas Heater: Vent-Free Infrared Gas Heater(18,000 BTU)

1 Answer

my 2520 water heater won't stay lit for just the shower all other water sources work fine the flame goes out when we turn on the hot water for the shower Replace thermocouple

Ad

Question about Desa Vent-Free Infrared Gas Heater: Vent-Free Infrared Gas Heater(18,000 BTU)

1 Answer

...not stay lit I have a Glo Warm heater that is mounted on the wall. The heater will not work on just the pilot and the lowest setting. Could it be the thermocoupler? yes for sure it's the ...

Question about Desa Vent-Free Infrared Gas Heater: Vent-Free Infrared Gas Heater(18,000 BTU)

2 Answers

INFRARED HEATER WILL NOT STAY ON. PILOT KEEPS GOING OUT AND UNIT WHEN I TURN THE PILOT ON AND THEN GO TO TURN THE GAS DIAL AROUND TO TURN THE GRATES ON, THE PILOT WILL SHUT OFF. WE HAVE TO BLOW AND ...

Question about Desa Vent-Free Infrared Gas Heater: Vent-Free Infrared Gas Heater(18,000 BTU)

1 Answer

heater will heat up the water then after a few moments it will go cold for a few seconds then hot then cold. It makes for a very uncomfortable shower. how much water pressure do you have, it should be

Question about Desa Vent-Free Infrared Gas Heater: Vent-Free Infrared Gas Heater(18,000 BTU)

2 Answers

...Infrared Comfortzone heater model #1500P displaying error message doFL. How do I get rid of it? According to the call line, hold down the up, down and enter buttons all at the same time and it should ...

Question about Desa Vent-Free Infrared Gas Heater: Vent-Free Infrared Gas Heater(18,000 BTU)

1 Answer

...heater has an additional wire that the univeral thermocouple does not have - where can i find an oem or will the universal one work You will have to order the correct part from Rinnai. If you are ...

Question about Infrared Quartz Heater Oak Cabinet LS-1500-6 HOM

1 Answer

...infrared heater home heater makes a screeching noise unit makes a screeching noise at intervals while operating. Works, but is annoying/worrying. That will be the fan and dry bearings on the motor. ...

Question about Infrared Quartz Heater Oak Cabinet LS-1500-6 HOM

1 Answer

...infrared heater E1 show up as soon as its turned on E1 is an error code that may be displayed on a Lifesmart infrared heater. It typically indicates a problem with the heater's thermostat or ...

Question about Infrared Quartz Heater Oak Cabinet LS-1500-6 HOM

1 Answer

...infrared heater? Are you seeing an E1 code on the display and wondering what it means? Don't worry, you're not alone. Many American Comfort infrared heater owners have experienced this issue and are ...

Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top Heating & Cooling Experts

Paul Carew

Level 3 Expert

3808 Answers

john h

Level 3 Expert

29494 Answers

Brad Brown

Level 3 Expert

19187 Answers

Are you a Heating & Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...