Question about Daewoo Heating & Cooling

1 Answer

I have aDSA-240-R split AC. The fan control is stuck on low and I am getting icying. I need the capacitor #402078, SH. Capacitor IEC 252 400VAC 25/70/21-PO-ClassB, DMB-4JJ002 50/60HzCan you help me?

Posted by on

Ad

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    President:

    An expert whose answer got voted for 500 times.

  • Master
  • 2,047 Answers

Getting such parts like capacitors usually depend on your location. but the best place to get them online are usually E-bay.com and amazon.com. Although you can find them in hardware stores near you if you cant wait for them to be deliverd from the purchase site but it is guaranteed you will get them from ebay and amazon. if you need more assistance send me your location so i can help you try to locate a hardware store lose to you.
Hope this solution has been helpful?

Posted on Mar 21, 2011

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi there,
Save hours of searching online or wasting money on unnecessary repairs by talking to a 6YA Expert who can help you resolve this issue over the phone in a minute or two.

Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.

Here's a link to this great service

Good luck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

I HAVE 1.5 TON SPLIT A/C WHAT SIZE OF RUNNING CAPACITOR WILL WORK IN COMPRESSOR?


the capacitor that is required is the same size as what is fitted
it will read as voltage and uf number
best have a ac technician check it out as it may not be the capacitor but the power board
some ac units have a capacitor that is in effect two capacitors in one to run the compressor and the cooling fan as well
best get the technician in as it could save a lot of money in the long run

Aug 08, 2015 | Dayton Permanent Split Capacitor Motor Fan

1 Answer

E4 error on screen


Check out door unit. May be weak in Running capacitor/Fan motor capacitor/Condensor coil dust blocked. First clean and run, if still problem check speed of fan motor, if less replace fan-capacitor.

May 07, 2014 | Midea 24,000 Btu 17 SEER Inverter Mini...

1 Answer

Condenssor fan moter not working


The condensor fan is usually a capacitor start capacitor run motor.To test i switch the unit on as normal then carefully flick the fan around in the direction of rotation (you may have to take the grill off) to do this,do not use your hand! If the motor starts to run it will be a faulty capacitor, do not leave it running for long as it will not run at full speed and will trip on thermal O/L or burn out.This is a common fault on AC split phase motors that use a capacitor for either starting or start and run.

Feb 03, 2013 | LG LS-L1210CL Mini Split Air Conditioner

1 Answer

Compressor just stopped working, does not cyle on for cooling


1. Is there high voltage(240 volts) power to the condensing unit?
2. Is there low voltage(24 volts) to the contactor?
3. Is the contactor pulled in and allowing 240 volt power thru?
4. Does the capacitor look burned or misshapen, is the top of the capacitor domed up?
If so the capacitor is bad and needs replacing.
If you have all the above items and the capacitor is good(the condensor fan should be running) and the compressor is still not running, then you need a professional to diagnose why the compressor is not running.

Sep 02, 2011 | Carrier 38CKC036 Air Conditioner

1 Answer

Split AC capacitor fused.


You need to trace the wires back to the device ie compressor, the fan now then write the color down. Note the capacitor has two different sides to it herm which is compressor and fan. then the common in the middle. Take the compressor wire should only be one and connect it to the herm. Now take the fan should only be one again and connect to fan. two devices connected. You might have two more wires and they go to the common. If you need any more help just get back to me. ken

May 09, 2010 | Samsung AW0603B Air Conditioner

2 Answers

Electrolux split AC 1.5 ton inside fan working.But out side compressor fan stops after two or three rotations.


The 2 most common issues are a freon leak or the outside unit fan start capacitor goes out. It's more likely a capacitor issue. They fail regularly, especially when it's hot out. I had a fan capacitor go out on one of my 3 units last year and it cost close to $300 for an AC company to come out and fix it. I watched them fix it and it's something that you can do yourself if you know what you're doing and are careful to hook it up right. I have three AC units and another capacitor went out this year and I found a kit with detailed instructions with pictures and phone support at hvacrepairkits.com. It saved me over $200 on the capacitor replacement.

Mar 21, 2010 | Heating & Cooling

1 Answer

Ac unit fan does not turn unless i force it to turn. also not producing cold air


If the fan just hums and if you spin the fan and it runs, check out the capacitor, it is bad. Most condensing units have a split capacitor, for the hermedic unit and the fan. If the compressor runs the dual capacitor is bad on the fan side. Your choice buy the dual capacitor, or just buy a single capacitor for the fan part of it. Make sure the voltage rating and microfarad ratings are the same. They will be marked on the old capacitor, as will fan (for fan), and herm for compressor). THATS 220 VOLTAGE YOUR WORKING WITH, BE SURE THE POWER IS OFF!!

Jun 22, 2009 | Goodman Heating & Cooling

3 Answers

Amana 1 ton Residential AC / Outside unit comes on for a sec


open the service panel to check for control voltage of 24volts when tstat calling, The contactor should be pulled in, if contactor is down,and contacts appear to be clean, and the unit is still not running, it is a bad compressor. to test this unplug the black wire from the compressoror at contactor,w/ power off! Turn on power if fan works normally it's a bad compressor. However if you see a swollen split cap(5 wires to a soup can looking w/ the terminal C,F,and Comp), switch it first and start at square one.
You also need to consider the high pressure switch if its cycling on off on off.

Mar 12, 2009 | Heating & Cooling

Not finding what you are looking for?
Heating & Cooling Logo

Related Topics:

58 people viewed this question

Ask a Question

Usually answered in minutes!

Top Daewoo Heating & Cooling Experts

Tim Whalen

Level 3 Expert

3074 Answers

armandog07
armandog07

Level 2 Expert

66 Answers

Steve

Level 3 Expert

3289 Answers

Are you a Daewoo Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...