Proper refrigerant levels for Amana Side by Side refrigerator

What is the proper refrigerant level and or suction and head pressures for an Amana 22 cu. ft side by side refrigerator?

  • Anonymous Jun 07, 2010

    Total waste of time and money! Any service person should know that R-22 is not used in refrigerators. Get your information right before claiming to be an expert! I found the information free of charge by doing a little more digging on the internet - maybe you should try it also

×

1 Answer

Shehu Pro

Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

  • Master 1,284 Answers
  • Posted on Jun 03, 2010
Shehu Pro
Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Joined: Dec 07, 2009
Answers
1284
Questions
4
Helped
334467
Points
3802

Hi, normally the suction pressure on a refrigerant -22 system will be between 60 pounds gauge pressure (which keeps it above freezing point) and about 80 pounds. This depends on the temperature condition.Make sure that the superheat and subcooling are correct to see what is to be considered normal for the conditions you have present.

Take care

  • Anonymous Jun 04, 2010

    What I need to know is how many ounces is the required amount of refrigerant. This unit uses 134a and I need to know what the suction pressure should be. The solution you gave me is of no value to me.

×

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

My santa fe compact 2 has ice build up on the coils what could it be?

Low refrigerant levels can cause ice build-up on your AC unit. If refrigerant levels drop, the refrigerant pressure inside your evaporator coil drops below freezing and thus the coils ice up because humidity freezes on the coils. The refrigerant pressures need to be checked and refrigerant added to achieve proper cooling without ice building on the coils.
0helpful
1answer

Amana drs2663bw ice maker drips water into the back of the ice bin forming an ice build up

Make sure your refrigerator is level. also check that the ice maker inside the refrigerator is level after leveling the fridge.
0helpful
1answer

Amana side by side refrigerator freezer making grinding noise but stops when door is open

make sure that it is level,does it rock some if so adjust the levels on the bottom of it
1helpful
1answer

How do you tell if a goodman ck36-1b has proper level of freon.Lets say it is 75 degrees outside and I added to where the low side reads around 30 and the high side is around 120-130.(orignal problem was...

The correct way is to evacuate the system,pull a vacuum then charge with a refrigerant scale.
In lieu of that you can charge by pressure and get close.
Normal operating pressure would be 68 psi on the suction side and about 225/275 on the high side.
You do have to calculate the outdoor and indoor ambient temperature.
At your 75 degree outdoor air a low side pressure of 60 psi or higher would be acceptable.
Your 30/130 is too low.
Add more refrigerant.

Make certain the indoor coil is clean and the fan motor is working correctly.
Have the leak repaired.
0helpful
1answer
0helpful
1answer

How do you check to see if the high side is leaking back into the low side on a scroll compressor suction pressure is 90psi R-22 suction line is warm but not hot

90 psi is very high for R22....low for R410 refrigerant. If leaking by the head pressure and suction pressure will be close to to the same reading
1helpful
1answer

I'm getting water underneath my crispers. Can you tell me what the problem is? It is a bottom freezer Amana. Thanks

Your refrigerator has a drain that leads to the exterior drain pan beneath the refrigerator. Occasionally this drain can become clogged resulting in standing water inside your refrigerator. A similar drain exists in the freezer, which when clogged results in ice build up on the floor of the freezer.

The drain is located either on the floor of the refrigerator, beneath the vegetable crisper, or in the wall behind a drain funnel.

Clear the drain by forcing a solution of water and bleach or water and baking soda into it with a basting syringe. If the solution will not flow through, slide a length of ¼ inch flexible tubing into the drain tube to push the clog through to the drain pan. Remove the tubing after clearing the clog.

NOTE-(This may be a leveling issue as well)

It is important for the refrigerator to be level. If it is not level, doors may not open or close properly and may not seal tightly. Also, drainage from the defrost cycle might be impaired as might the ice making cycle. The appliance was engineered based on it being installed in a level position. While there may be some tolerance for out-of-level installation, the appliance will operate at its best when properly leveled.

Place a level on top of the refrigerator near the front. Do not put it on the door because the door may not be aligned with the refrigerator case. Check that the refrigerator is level from side to side. Next turn the level to check that it is level from front to back.

If it is not level, adjust one or more of the adjustable leveling feet until it is level. The feet are bolts that can be turned to raise or lower the refrigerator. If they cannot be adjusted with your fingers, use a crescent wrench or pliers.

If you have an ice-maker, it should also be checked for level after first leveling the refrigerator. An ice-maker that is out of level will spill water into the ice bin or into the freezer. It can be repositioned by loosening the mounting screws, adjusting it for level and then re-tightening the screws.
0helpful
1answer

Operating pressures for 134A refrigerant system

I would go for 40 on the suction and 150 discharge, or divide the locked rotor current by 6 and charge so the current is 1/6 of the locked rotor current of the compressor, or by temperature/pressure relation 110* discharge and 35* suction, or get the suction line sweating. The best way is to remove all the refrigerant and then weigh the refrigerant the system is designed for on these critical charge appliances.
Not finding what you are looking for?

435 views

Ask a Question

Usually answered in minutes!

Top Amana Refrigerators Experts

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

Brad Brown

Level 3 Expert

19187 Answers

Are you an Amana Refrigerator Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...