RPM/voltage fluctuation on Guardian Primepact 50G

Under no load RPM sags and the voltage sags from 120v to 112v and then comes right back up to 120v with RPM increase. Under load the same thing happens but with a smaller range 115V to 110V. Just had new crank seals installed by a Generac shop with 30 years exp. Prior to service it had a 1 or 2 volt fluctuation no load and stable inder load.

Posted by on

Ad

2 Answers

  • Level 1:

    An expert who has achieved level 1.

  • Contributor
  • 1 Answer

The voltage regulator board on this unit is notorious for failing. If you are handy, you can replace it yourself with basic tools and a voltmeter to set the output. The part is about 200 dollars. Good luck

Posted on Sep 06, 2010

Ad
  • Level 1:

    An expert who has achieved level 1.

  • Contributor
  • 1 Answer

Go to www.zabatt.com - look in their Service manuals section - good luck!!

Posted on May 28, 2009

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of.(from cars to computers, handyman, and even drones)
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Output of generator is lower voltage than it should be usually 440v now 395v? reasons?


possible that the rpm of the gen set is lower than normal
there is an adjustment screw that adjusts the spring tension for the governor and it can be adjusted to bring the voltage back to normal
Note here--- if you run the set with a load of around 1/2 capacity set the voltage to on the 440 volts
if you run it at near capacity set it above voltage (445) because as it comes under load the rpms drop and the voltage comes back to normal

Nov 08, 2016 | Electrical Supplies

1 Answer

Why generater not increasing revs under load


it depends on the load. If it is a Light or two, the generator is happy producing voltage at the RPM it is already at.

May 26, 2014 | Homelite Electrical Supplies

1 Answer

I have a Guardian RV 3600 watt generator than wont run more than a few seconds. I have to hold my hand over the breather to get it to fire then as soon as it revs up it shuts off.


carburetor restricted due to long time storage drop carb fuel bowl unscrew the jet and pull down the fuel tube clean them and your generator should run much much better

Aug 16, 2013 | Guardian Rv Generator 4800 Watt, Gasoline,...

1 Answer

Charger not charging and motor runs fine


You need to check the rectifier first to make sure it has AC power on the 2 x AC terminals and 13.8V DC on the DC side, if you have AC and no DC replace the rectifier, if you have no AC check the stator windings

Jun 10, 2013 | Guardian Rv Generator 4800 Watt, Gasoline,...

1 Answer

Engine is stalling when turning right


H JL, As the problem is apparent only when turning right, I believe there is a problem with the idle up solenoid or the vacuum pipes connected there. The unit is situated on the steering box and increases engine RPM when the engine comes under increasing load, when demand is increased while turning. Regards John

May 01, 2013 | 1990 Nissan Pathfinder

1 Answer

Where is the starter on a primepact 50g


follow red thick wire on right side of the solenoid the starter is on right side rear hidden by the air box that surrounds the gen.

Aug 01, 2012 | Guardian Rv Generator 4800 Watt, Gasoline,...

1 Answer

I purchased a Coleman Powermate 5000 6 years ago: Ser: 94411583. Never really used it for any length of time. Kept for emergency. An electrician checked it for voltage output a short time ago. 240V...


Voltage is adjusted by raising or lowering the engine speed (governor adjustment), however one must also pay attention to the rpm because your generator was designed to produce 120 volts at 60 cycles while turning 3600 rpm. Your electrician should have tested for htz while testing for voltage. I would recommend re-testing under load and adjust governor to turn 60 cycles to see resulting voltage.

Sep 30, 2010 | Coleman Powermate Powermate 5000W...

1 Answer

My generac 40g rv generator will start fine but no power. I noticed that when it starts the microwave will power up for just a second. I can turn the generator off and on a couple of times and then it will...


It may be demagnetised. If you turn off the generator before unplugging the load this may happened. Try to put a strong magnet (like those from loudspeakers) in contact with the body of alternator. I do this in the past and it work.If you do not know how to do this ask an electrician, he can help you .

Sep 30, 2010 | Guardian Rv Generator 4800 Watt, Gasoline,...

1 Answer

My generator is not putting out the proper voltage? it's only putting out approx 75 volts on the 120 volt circit. i adjust the idle to full out and i get approx 112v.


Most low voltage conditions on generators are simply due to a low engine rpm. Most modern generators are 2- pole windings. So your engine rpm should theoretically run @ 3600 rpm. which will produce 120/240 volts @ 60 HZ. In actuality You want to set your rpm's @ Approx. 3720rpm no load. About 62.5 Hz. Without getting to technical this will give you your desired 120/240 volts loaded. Hope this helps.

Aug 09, 2010 | Northstar Electrical Supplies

1 Answer

I have a new Guardian 40G generator that won't start (correctly, anyway). When I squirt gas into the intake it runs until that is gone then dies. The fuel pump is pumping gas to the carb. but it seems to...


Try to measure the voltage at the connector when trying to start.
If it is 12 V and the engine does not start - disconnect it and try again.

Have in mind that you must have protections (Shut down):
  1. Low oil level;
  2. Low oil pressure;
  3. High temperature.
and this valve may be responsible for them.

Jun 20, 2010 | Guardian Rv Generator 4800 Watt, Gasoline,...

Not finding what you are looking for?
Guardian Rv Generator 4800 Watt, Gasoline, Primepact 50G Logo

642 people viewed this question

Ask a Question

Usually answered in minutes!

Top Guardian Electrical Supplies Experts

 Kenneth
Kenneth

Level 2 Expert

50 Answers

Roland W VanLue
Roland W VanLue

Level 3 Expert

486 Answers

Are you a Guardian Electrical Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...