Konica Minolta bizhub 350 All-In-One Laser Printer "reset fuser counter" Questions

Ad

Question about Konica Minolta bizhub Office Equipment & Supplies

4 Answers

...fuser counter or 36=>counter clear(items 8)=>Clear fuser counter. the fusers have an inline fuse soldered on the plug which resets an internal counter. if you pulled a fuser from ...

Ad

Question about Konica Minolta bizhub Office Equipment & Supplies

1 Answer

...reset fuser counter without replacing the fuser on a C352 bizhub? You can. You have to remove the fuser, and replace the counter reset fuse that is soldered into the wiring harness, then re-install ...

Ad

Question about Konica Minolta bizhub Office Equipment & Supplies

3 Answers

...fuser unit you have to ececute a "trouble reset". Turn on your machine by press and hold "utility counter" botton, after some seconds press to display "TROUBLE RESET" and turn off and on machine. ...

Question about Konica Minolta bizhub Office Equipment & Supplies

1 Answer

fuser high temperature? how to repair and what im doing? in main screen press the utility counter the touch chick details when screen is coming press stop00stop01 and type password is 00000000 after ...

Question about Konica Minolta bizhub Office Equipment & Supplies

1 Answer

...will get a "OK" message. Turn the main power off for 10 seconds and turn back on. If message returns you must replace the fuser. Attempt Trouble reset again at your own risk!! Fusers are a Fire ...

Question about Konica Minolta bizhub Office Equipment & Supplies

1 Answer

fuser temperature too low error code could be the thermistor or heat lamp is not comming on to reset the error code turn the main switch off the main switch is located on the left side opf the machine

Question about Konica Minolta bizhub Office Equipment & Supplies

1 Answer

...RESET CONTINUES FUSER CATCH ON FIRE RUINING A PERFECTLY GOOD DAY have the fuser replaced 1. Turn OFF the Main Power Switch. 2. Turn Main Power Switch ON while pressing the Utility/Counter key. 3. ...

Question about Konica Minolta bizhub Office Equipment & Supplies

1 Answer

...and nothing the message still in the scren waht can i do\/ you need to replace a whole new fuser or come with full new PIKO fuse to reset the fuser counter, its useless if you change an used

Question about Konica Minolta bizhub Office Equipment & Supplies

1 Answer

...reset, you are messing with the Fuser the Hot part. Continuing to reset without a technician looking at and or replacing it, the fuser can catch on fire and that would ruin a perfectly good day. Then ...

Question about Konica Minolta bizhub Office Equipment & Supplies

1 Answer

...reset the fuser life counter. You will have to remove the fuser, remove the fuser bottom cover (one screw), cut out the fuse and solider in a new fuse. You must turn off and unplug the copier before ...

Not finding what you are looking for?
Konica Minolta bizhub 350 All-In-One Laser Printer Logo

1,100 questions posted

Ask a Question

Usually answered in minutes!

Top Konica Minolta Office Equipment & Supplies Experts

Norman Weimar
Norman Weimar

Level 3 Expert

7035 Answers

Cindy Wells

Level 3 Expert

6688 Answers

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Are you a Konica Minolta Office Equipment and Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...