Hi,
This kind of symptoms indicated that the voltage regulator IC (BA4916) is already faulty. It gone to overload after a while of operation and shutdown itself. I will recommend you to replaced also the following capacitors.
C227 - 10uf/16v
C229 - 10uf/16v
C225 - 100uf/16v
C228 - 47uf/16v
C224 - 22uf/16v
These capacitor filter the voltages in and out of IC102(BA4916).
Your unit will back to normal again after the said parts have been replaced.
Hope I help you.
Have a nice day!
Thanks for using Fixya.
Best decision that the unit has been checked by an expert to confirm where the exact fault came from and determine if my solution is accurate or not...
I'm aldo glad that your unit had been fixed and my solution was accurate. If it is possible, please rate my solution. Again thanks for visiting Fixya.
×
219 views
Usually answered in minutes!
Thank you for your advice but not fixed as yet? The info you sent has been forwarded to expert here in Sydney - awaiting outcome?
My Clarion has been fixed,and your advise is the solution
Thank you very much
Regards Frank
My Clarion. has been fixed thanks to your suggestion,Iam Happy thank you regards Frank
×