I notice that I have the same problem and the wire coming out of the frame on the outside opposite where the thermocouple attaches to the frame on the inside goes nowhere. Shouldn't that wire connecting to something? If so, exactly where is the point of attachement of that wire? It should control the opening of the main gas value somehow.
Richard
SOURCE: Empire BF-30-1 Main Burner problem
flame sensor,just take some fine sand and lightly sand,it will be where the flame hits one of the burners,should look like a probe,if this helps please give me a fix ya
SOURCE: Empire DV-210: Pilot light will light and stays lit, but when I
The thermocoupler is no good. It's that bulb sitting in the pilot flame. when it goes out it shuts everything doen in the main valve. It has to be kept hot by the pilot, that's how it know whether or not it is safe to open the main .
SOURCE: pilot lights but no main burner
Is there a way to check for gas pressure even if just a slight loosened connection to hear it then quickly re-tightened. Otherwise the main valve is not working as it should and will need to be serviced or replaced. Thats all i got.
392 views