1 Answer

Ok I had the problem with ruud uaka-030jaz. I think i hit the wrong buttons when sent your solution so im not sure my response went to u. I checked the outside disconnect..says on the panel it does not have fuses inside. I checked behind the plastic panel anyhow and there weren't any. Did check the screws on the wires to be sure they were tight. I also was looking close at the contactor and there does appear to be some scorching under the contacts that are controlled by the spring loaded part. they rnt large marks but they r black. could this be bad?

Posted by on

Ad

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Master
  • 11,800 Answers

Very bad - the burned part signals that there has been an short somewhere. The fact that the burned part is black signals that the short has been massive so it's probably in the compressor itself which means that the repair will be costly. Call a pro home to give you a quote, the bill may end up higher than your aircon is worth.

Posted on Jul 20, 2010

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya Repairman can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repair professionals here in the US.
click here to Talk to a Repairman (only for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Where can I purchase a run start capacitor for a RUUD air conditioner model # UAKA-030JAZ


Most big box stores do not carry these type of parts.You are supposed to be a licensed contractor to buy at a heating & cooling supply company. Not knowing were you live I can not recommend a supplier. I am in the Cleveland Ohio area. If you can not find it locally I can ship it for you.

Jul 04, 2014 | Ruud UAKA030 Air Conditioner

1 Answer

Ruud UAKA-030JAZ fan spins, not blowing cold air


there are 3 things to be considered,first,if the compressor motor `s connectors are having loose,it gives a hi ampere to your RELAY that can cause to its contacts being fried,second,the compressor motor itself is gaining a hi ampere already i.e. having unusual sound that can cause heavy friction inside the turning mechanism and third the last but not the least,maybe this time,the tubes or the compressor itself having very small holes that causes to the refrigerant to escape and it doesn`t gives off cold air.

Apr 17, 2014 | Ruud Heating & Cooling

1 Answer

Freezing pipes and water dripping on to motherboard of the heater in a Ruud UAKA-030JAZ system. Help?


More than likely, the system is low on refrigerant and the copper line-set is freezing up and water is dripping onto the board in the furnace (and other things) because it is an upflow system with the evaporator coil on top. Other things to check would be:
1. Dirty/clogged filters in the return air system.
2. Fan motor not working inside furnace. (The Blower)
3. Coil dirty/clogged which could be checked by the amount of airflow coming out of the vents. This would have to be cleaned by a technician.

Most of the time, it is the charge which also means there is a leak in the refrigerant system somewhere and needs to be fixed. Hope this helps you out! Good luck.

Jun 19, 2012 | Ruud UAKA030 Air Conditioner

2 Answers

Model UAKA 030JAZ was working fine. Now, the compressor fan does not come on and neither does the compressor. I don't know how the contactor works but it is not engaging (the spring loaded contacts are...


Hello
You need to complete the 24 volt circut from the themostat to the transformer to get the contactor to pull in.

Check for voltage at the transformer,should be 120 v in 24 volts out.Also there may be a small reset button on the transformer.

Apr 18, 2011 | Ruud UAKA030 Air Conditioner

1 Answer

I am trying to find a parts list for a RUUD UAKA-030JAZ air conditioning unit (specifically the compressor/condensor contactor).


RUUD will only sell there factory parts to certified contractors. My advice to you is to find a local HVAC parts distibutor that will sell you generaric parts which will work just as good as the factory parts.

Jun 23, 2010 | Ruud UAKA030 Air Conditioner

1 Answer

We need an owners manual.


Hi, looks like you have a 21/2 ton Ruud split system by the numbers. Let me look this up and see if I can find a manual for this unit and send you a link to down load it. Give me sometime please. Be back soon.
Shastalaker7

May 08, 2010 | Ruud UAKA030 Air Conditioner

1 Answer

Ruud UAKA-037JAZ A/C How do i determine how many ton unit it is?


its a 3 ton i went to ruud and looked it up for you.

Jul 31, 2009 | Heating & Cooling

Not finding what you are looking for?
Heating & Cooling Logo

Related Topics:

142 people viewed this question

Ask a Question

Usually answered in minutes!

Top Heating & Cooling Experts

Paul Carew

Level 3 Expert

3087 Answers

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

Tim Whalen

Level 3 Expert

3074 Answers

Are you a Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...