Anonymous Posted on May 31, 2010

Central air unit compressor won't run. low side is 120+ psi and high side is 178 psi. what reasons would cause this.

1 Answer

Anonymous

Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

President:

An expert whose answer got voted for 500 times.

  • Master 1,902 Answers
  • Posted on May 31, 2010
Anonymous
Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

President:

An expert whose answer got voted for 500 times.

Joined: Feb 04, 2009
Answers
1902
Questions
0
Helped
902981
Points
6294

You will need to replace the run capacitor on your unit. I will also give you the link to a great website that you should keep in case you have other issues with your unit you can always refer there to the most common causes of AS units not working. But what you have said is a VERY common sign that the run capacitor is bad and needs to be replaced;

http://toad.net/~jsmeenen/compressor.html

  • Anonymous May 31, 2010

    air conditioner has only one compacitor, must be start and run. you still think it is the compacitor?

×

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1helpful
2answers

When i turn on the a/c,the compressor does not work

CHECK REFRIGERANT CHARGE. USING A MANIFOLD GAUGE SET. HOOK MANIFOLD GAUGE SET TO LOW PRESSURE PORT AND HIGH PRESSURE SIDE PORT. LOW SIDE PRESSURE SIDE SHOULD HAVE 25 - 36 PSI AND HIGH PRESSURE SIDE SHOULD BE 178 - 237 PSI. IF LOW SIDE PRESSURE SIDE READ BELOW 20 PSI THE LOW PRESSURE SWITCH WILL NOT TURN ON THE AC COMPRESSOR CLUTCH NEED TO ADD LITTLE MORE REFRIGERANT. IF REFRIGERANT LEVEL CORRECT CHECK AC COMPRESSOR FUSE AND RELAY.IF POWER GOING TO AC COMPRESSOR CLUTCH YOUR COMPRESSOR CLUTCH HAS OPEN WINDING. AC COMPRESSOR CLUTCH NEED REPLACING.
0helpful
1answer

What does it mean when the High side gauge is below 100 psi on my central air

It could be several things.I would start by making sure that the compressor is working.Check high and low pressure while unit is running. If they both read the same then your compressor is not working.The first thing I would do is to add refrigerant to see if it is just shutting down due to low pressure.Depending on how old your unit is and what type of gas you are using you should see pressures on the high side from 250-350 and low side between 55-85.Hope this helps you. Thanks.
2helpful
1answer

1997 jetta ac works for one minute then warm air blows

check the refrigerant level. The compressor is running until the low pressure or high pressure switch switch cuts it off.

Running the unit without enough refrigerant will damage the compressor because the lubricating oil is dissolved in the refrigerant. This is the reason for the low pressure switch cut off--to protect the compressor from damage.

If pressure gets too high, the compressor seals will blow. Thus the reason for the high pressure switch. Too much refrigerant or too much air in the system (due to a leak) will cause high pressures.

If refrigerant level appears to be correct, then suspect trapped air from a leak causing a high pressure cut-off. If refrigerant is low, suspect a leak causing a low pressure cut-off.
0helpful
1answer

24ABR348A0031010 compressor starts then stops. Carrier 4 ton R22 unit. Worked great, then fan runs all the time. Compressor will start for less than a minute, then stop. Basically compressor will not stay...

Hello RR Hard start can't hurt BUT dosen't sound like the problem.Do you have a scroll compressor?They don't need a kit.Does it start every time?It could be short cycling on LOW PRESSURE SWITCH.If the unit is (pumping down) during the run time you have a restriction in the system.Make sure the service valves are open ,do you have a filter dryer colgging up or a bad TXV valve also could cause short run times.20-30 PSI the switch cuts out.
3helpful
2answers

What is a/c pressure on a 1999 kenworth when fully charged with a c 15 cat 550 hp tx KIETH.

low side psi will run about 30 psi, hi side pressure will go as high as 350 psi then the pressure switch will kick the engine fan on then drop psi down to 120-150 psi
0helpful
1answer

Hi everybody i want some help , iam a technision in air conditions ,i was fix a central ac carrier and i found that everything works good the compressor and the high pressure fan and indoor fan ,but the...

if the compressor is running - the suction pressure should be 65-75 psi - if it is very low - not enough freon - if it is very high - the compressor valves could be damaged - both will cause this
1helpful
1answer

I am replacing my central A C. with a new one. I worked on Autos for 50 yrs. have guages. Do I Screw the Allen Plug in on the high side, run the compressor, then screw in the low side. to keep the r-22 in...

By George, you've got it.Front seat (screw in) the high side and run the unit. Do not let it pull into a vacuum as this will allow air to be sucked into the system when you open it. Also, watch you high side gage. Don't go over 400 psi. This is usually the High pressure cut out setting on most safeties. Pull low side to about 2-3 psi and kill unit. Let sit for about 5 minutes and then run it again back down to 2-3 psi. Front seat the low side any you should be good to go.
I strongly suggest that you add a filter/dryer to the system. It's good practice to do so once the system has been open. If you are going back with a 410-a system, don't leave it open to the atmosphere for more than 15 minutes. That is, the condensing unit. The only way to remove moisture from the oil on this system is to use filter/dryers. You can not vacuum it out like in the old days with R-12.

Good luck and hope this is what you are looking for.
2helpful
1answer

Not pumping up to capacity, motor and compressor working fine,

If your pump is shutting off before it reaches it's max psi. then you need to adjust you switch. Under the black case there are two adjustment screws. One is the high\low adjustment, the other is high pressure cut off.
The first will change when the pump turns on and off for your low psi setting and the high setting simultaneously.
The second will allow you to raise or lower just the high setting. There should be a diagram under the black cap to show which is which. Adjust the high side only and just a 1\4 turn then run the compressor and see if that takes care of the high setting.
0helpful
1answer

Restriction

The cap tube is clogged and the unit is overcharged. Get used to this on beverage air units.
Not finding what you are looking for?

39 views

Ask a Question

Usually answered in minutes!

Top Heating & Cooling Experts

Paul Carew

Level 3 Expert

3808 Answers

john h

Level 3 Expert

29494 Answers

Brad Brown

Level 3 Expert

19187 Answers

Are you a Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...