SOURCE: HOBART FRYER CK20
Most likely solution is to replace the reset. If the new reset trips, check the amperage on the elements. At 208V all three phases should be around 47A, 480V around 20A each. Check all wiring connectors for good connections and no evidence of corrosion or overheating.